IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Dergisi
  • Volume:6 Issue:2
  • Polipirolün Yüksek Performanslı Sıvı Kromatografide Potansiyometrik Dedektör Olarak Kullanımı...

Polipirolün Yüksek Performanslı Sıvı Kromatografide Potansiyometrik Dedektör Olarak Kullanımı

Authors : Sabriye PERÇİN ÖZKORUCUKLU, Yücel ŞAHİN, Güleren ALSANCAK
Pages : 127-139
View : 19 | Download : 11
Publication Date : 2011-12-01
Article Type : Research Paper
Abstract :Özet: Bu çalışmada 4 adet sülfonamit grubu bileşiğin insert ignore into journalissuearticles values(sülfonilamit, sülfodiazin, sülfometazin, sülfomonometoksin); kromatografik davranışları, polipirolün potansiyometrik dedektör olarak kullanıldığı HPLC yöntemi ile incelenmiştir. %15, 30, 40 ve 50 insert ignore into journalissuearticles values(v/v); asetonitril-su ikili karışımlarında pH 1,5-7,0 aralığında hazırlanan Britton-Robinson tampon çözeltileri kullanılarak asetonitril-su oranı ve pH etkisi belirlenmiştir. Polipirol potansiyometrik dedektör, camsı karbon yüzeyinde pirolün elektropolimerizasyonu ile hazırlanmıştır. Bileşiklerin tayin limitleri sülfonilamit için 1,92.10-6 M; sülfodiazin için 2,12.10-6 M; sülfomerazin için 1,83.10-6 M; sülfomonometoksin için 1,25.10-6 M olarak hesaplanmıştır. Anahtar Kelimeler: Sülfonamit, Polipirol, Potansiyometrik dedektör, HPLC Abstract: In this study, the chromatographic behaviors of four sulfonamides insert ignore into journalissuearticles values(sulfanilamide, sulfadiazine, sulfamerazine, sulfamonomethoxine); were investigated by a HPLC using polypyrrole as a potentiometric detector. The effect of acetonitrile-water ratio and pH were determined for %15, 30, 40 and 50 insert ignore into journalissuearticles values(v/v); acetonitrile/water binary mixture between pH 1.5 and 7.0 prepared Britton-Robinson buffers,. The polypyrrole potentiometric detector was prepared by electropolymerization on the surface of glassy carbon. Detection limits of these compounds were calculated as: 1.92.10-6 M for sulfanilamide; 2.12.10-6 M for sulfadiazine; 1.83.10-6 M for sulfamerazine; 1.25.10-6 M for sulfamonomethoxine. Key words: Sulfonamide, Polypyrrole, Potentiometric detector, HPLC
Keywords : Sülfonamit, Polipirol, Potansiyometrik dedektör, HPLC

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025