IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Türk Doğa ve Fen Dergisi
  • Volume:11 Issue:4
  • EFFECT OF AZIMUTH ANGLE ON THE PERFORMANCE OF A SMALL-SCALE ON-GRID PV SYSTEM

EFFECT OF AZIMUTH ANGLE ON THE PERFORMANCE OF A SMALL-SCALE ON-GRID PV SYSTEM

Authors : Muharrem Hilmi AKSOY, İsmail ÇİYLEZ, Murat İSPİR
Pages : 42-49
Doi:10.46810/tdfd.1179350
View : 64 | Download : 10
Publication Date : 2022-12-28
Article Type : Research Paper
Abstract :Abstract: In this study, the effective solar irradiation on the PV surface, electricity generation, and performance ratios of a small-scale system were investigated for a 100 kW on-grid PV system in Konya, Turkey, by PVsyst software. Five different azimuth angles as -30°, -15°, 0°, 15°, and 30° were investigated for no-shading simulations with a fixed optimum tilt angle of 33°. As a result, the highest effective solar radiation comes to the system with an azimuth of 0° as 1966.4 kWh/m², which is 2.12%, 0.46%, 0.79%, and 2.66% greater than the other azimuth angles of -30°, -15°, 15° and 30°, respectively. On the other hand, it is seen that the highest energy production is obtained from the system with an azimuth angle of 0° with annual energy of 174.33 MWh. This value is 1.91%, 0.37%, 0.89%, and 2.8% greater than the other azimuth angles of -30°, -15°, 15°, and 30°, respectively. In addition, to evaluate the shading effect on the performance of the PV panels, two different panel spacings as, 4 m and 8 m, were also considered. It was seen that the electricity generation with an 8 m span system was 8.88% better than the 4m. Another finding is that the height of the panels is negligible according to electricity generation. Finally, the highest performance ratio is obtained from the azimuth angle of 0°, as 0.857.
Keywords : azimuth angle, performance ratio, PV performance, PVsyst, solar energy

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026