  • Estimation of Reference Evapotranspiration inside Greenhouses in Arid Condition

Estimation of Reference Evapotranspiration inside Greenhouses in Arid Condition

Authors : Abbas ERAHMA, Abdalla NO KHEIRY, Mysara Ahmed MOHAMED, Rihab HASSAN
Pages : 44-47
View : 22 | Download : 10
Publication Date : 2018-01-19
Article Type : Research Paper
Abstract :Because of the large area utilized by a class A pan, alternative methods have been used to estimate reference evapotranspiration insert ignore into journalissuearticles values(Et o ); inside greenhouses. The objective of this work was to compare ET o estimated by different methods inside and outside a greenhouse. A class A pan insert ignore into journalissuearticles values(CAP i );, lyismeter insert ignore into journalissuearticles values(L i ); and piche tube insert ignore into journalissuearticles values(PT i ); were installed inside a greenhouse, and another class A pan insert ignore into journalissuearticles values(CAP o ); was installed outside. ET o estimates, obtained by CAP i , PT i , and L i were 81%, 56% and 86%of those estimated by CAP o , respectively. A simple linear regression showed positive coefficients insert ignore into journalissuearticles values(R = insert ignore into journalissuearticles values(0.96); for the L i and the CAP i ,R = insert ignore into journalissuearticles values(0.95); for the PT i and the CAP i , R = insert ignore into journalissuearticles values(0.88); for the CAP i and the CAP o , R = insert ignore into journalissuearticles values(0.96); for the L i and the CAP o , and R = insert ignore into journalissuearticles values(0.82); for the PT i and the CAP o );. ET o needs to be estimated inside greenhouses and it is possible to use lyismeter or piche tube to estimate the ET o inside the greenhouse. Equipment replacement would increase the available space inside the greenhouse.
Keywords : Class A pan, lyismeter, piche tube, evapotranspiration, greenhouse

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.