  • Transcatheter Closure of Patent Ductus Arteriosus in infants between 2-10 kg

Transcatheter Closure of Patent Ductus Arteriosus in infants between 2-10 kg

Authors : Ahmet Vedat KAVURT, Seçil SAYIN, Bilal ÖZELCE, Denizhan BAĞRUL, Alper GÜRSU, İbrahim ECE, İbrahim İlker ÇETİN
Pages : 30-38
Doi:10.12956/tchd.1190725
View : 33 | Download : 12
Publication Date : 2023-01-30
Article Type : Research Paper
Abstract :Objective: The aim of this study was to present our experiences on transcatheter patent ductus arteriosus insert ignore into journalissuearticles values(PDA); closure with different devices, mostly the Amplatzer Piccolo Occluder, in infants weighing between 2-10 kg. Material and Methods : In this study, the files of 31 patients who underwent transcatheter PDA closure between December 2019 and August 2022 were reviewed retrospectively. Results: Transcatheter PDA closure was performed on 31insert ignore into journalissuearticles values(14 female); infants weighing between 2-10 kg. The mean age of patients was 10.7±6.7 months insert ignore into journalissuearticles values(2-28);, and the mean weight was 6.6±2 kg insert ignore into journalissuearticles values(3-9.9);. The median narrowest diameter of the ductus was 2.2 mm insert ignore into journalissuearticles values(IQR 2-3); and the median ductus length was 6 mm insert ignore into journalissuearticles values(IQR 4.75-8);. The procedural success rate of all interventional procedures was 88% insert ignore into journalissuearticles values(30 of 34);. Complications occurred in a total of four patients including failure of device implantation in one patient, post-procedural device embolization in 2 patients, and the significant residual shunt in one patient. None of the patients required surgery. In 34 interventional procedures, 3 of which were reintervention, 34 devices were used. Twenty-seven insert ignore into journalissuearticles values(79%); of them were Amplatzer Piccolo Occluder. The median fluoroscopy and procedural times were 10.5 minutes insert ignore into journalissuearticles values(IQR 7.25-18.5); and 40 minutes insert ignore into journalissuearticles values(IQR 35-57.5); respectively. The mean duration of follow-up was 10.3±8.8 months insert ignore into journalissuearticles values(1-32 months);. Conclusion: In our experience, transcatheter treatment of PDA with the Amplatzer Piccolo Occluder device which was our first choice for appropriate duct anatomy and size in infants weighing between 2-10 kg, is safe and effective.
Keywords : Amplatzer Piccolo Occluder, cihaz embolizasyonu, Prematüre bebek

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.