  • Ankara Üniversitesi Eczacılık Fakültesi Dergisi
  • Volume:49 Issue:1
  • DETAILED ELECTROCHEMICAL BEHAVIOR INVESTIGATION AND DETERMINATION OF ANTIPSYCHOTIC DRUG PALIPERIDONE...

DETAILED ELECTROCHEMICAL BEHAVIOR INVESTIGATION AND DETERMINATION OF ANTIPSYCHOTIC DRUG PALIPERIDONE ON A GLASSY CARBON ELECTRODE

Authors : Sariye İrem Kaya, Ece Ozkan, Nurgul Karadas Bakirhan, Sibel A Özkan
Pages : 1-11
Doi:10.33483/jfpau.1495986
View : 162 | Download : 145
Publication Date : 2025-01-20
Article Type : Research Paper
Abstract :Objective: A sensitive and cost-effective electrochemical method was developed on a bare glassy carbon electrode (GCE) for the determination of paliperidone (PAL), an antipsychotic drug used in the primary schizophrenia treatment affecting the whole world. Material and Method: The oxidation studies carried out in pH 8 phosphate buffer solution (PBS) by cyclic voltammetry (CV) showed that the oxidation reaction of PAL is a process including the same number of electrons and protons. The electrochemical detection of PAL was carried out by differential pulse voltammetry (DPV). Result and Discussion: The linearity range was between 1 µM and 100 µM. The limit of detection (LOD) and quantification (LOQ) values were calculated as 2.41x10-7 M and 8.033x10-7 M, respectively. The applicability of the developed method was confirmed by using it on synthetic human serum. The relative standard deviation (RSD) values were less than 2%. The selectivity of the analysis was demonstrated over against interfering substances such as ascorbic acid, KNO3, MgCl2, paracetamol, dopamine, Na2SO4, and uric acid with recovery% and RSD% values in the range 98.32%-101.56% and 0.15%-1.99%, respectively. The proposed method provided high sensitivity for PAL and is the first reported method for the electroanalysis of PAL.
Keywords : Camsı karbon elektrot, diferansiyel darbe voltametrisi, elektrokimya, paliperidon

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.