  • Academic Platform Journal of Natural Hazards and Disaster Management
  • Volume:2 Issue:2
  • The Risk Calculation of Hazardous Zones Created By Flammable And Explosive Chemicals, LPG Tank Examp...

The Risk Calculation of Hazardous Zones Created By Flammable And Explosive Chemicals, LPG Tank Example

Authors : Bülent BÜYÜKKIDAN, Hüseyin GÜMÜŞ, Ömer Ahmet USLU
Pages : 47-62
Doi:10.52114/apjhad.1024396
View : 45 | Download : 9
Publication Date : 2021-12-29
Article Type : Research Paper
Abstract :The determining of hazardous areas created by flammable and explosive chemicals is important to obtain a safe working environment. Taking precautions and prevent explosions require detailed investigations and accurate calculations instead of superficial and personal experience. In this context, possible leakages and leaks occurring around the LPG tank and its connections in a real enterprise were evaluated and the border of possible explosive atmosphere areas was calculated by the ALOAH program according to the TS 60079-10-1 standard. Based on the secondary discharge of the LPG from the bottom of the tank, the discharge characteristics were calculated as 4.946578 3.926692 m3/s at sonic and subsonic conditions respectively, and region radii, 10.8 m. The explosive atmosphere of the LPG tank was concluded that matched well the definition of Zone 2. The risk severity score of explosive atmospheres was calculated as 12 by using the risk assessment method of matrix system with approximations, possible in a week insert ignore into journalissuearticles values(3P);, and the effect that could cause serious injury insert ignore into journalissuearticles values(4P);. Serious threats and devastating effects were fictionalized clearly by explosion scenarios of the LPG tank. The calculations of explosive borders for flammable chemicals are necessary to prevent explosions, fires, and toxic effects of leaked chemicals by taking measurements on time. It is also necessary to calculate explosive areas and possible sceneries for each chemical separately for accurate results and effective control.
Keywords : Flammable and explosive chemicals, ATEX, hazardous environment, LPG

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.