IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Balkan Journal of Electrical and Computer Engineering
  • Volume:7 Issue:1
  • Optic Disc Segmentation based on Template Matching and Active Contour Method

Optic Disc Segmentation based on Template Matching and Active Contour Method

Authors : Seda ARSLAN TUNCER
Pages : 56-63
Doi:10.17694/bajece.470796
View : 22 | Download : 14
Publication Date : 2019-01-31
Article Type : Research Paper
Abstract :This paper proposes a hybrid method that is capable of automatically implementing the Optic Disc insert ignore into journalissuearticles values(OD); segmentation. In the hybrid method, two steps were performed. First, the location of the OD was determined by template matching. Second, the OD location coordinates obtained in the first stage were given as inputs to the Active Contour Method applied to complete the OD segmentation. Furthermore, as part of this study,  Android based a program was developed to allow physicians the ability to independently access the proposed hybrid method results from anywhere and to add comments. Thus, the physician would be able to instantly track the patient. Performance evaluation of the proposed hybrid method was done separately for both localization and segmentation. The success of localization was confirmed on the basis of whether the determined coordinates corresponded to the OD. The segmentation process was assessed according to the parameters, as derived from a confusion matrix. The average Dice coefficient obtained for all images was 0.943, while the average values of accuracy, specificity and sensitivity parameters for all images were calculated as 0.90, 0.961 and 0.931, respectively. The final results obtained from the proposed hybrid method were checked by a physician, who observed that the OD was successfully segmented.
Keywords : Optic Disc, Active Contour, Template Matching

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025