IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Bitlis Eren University Journal of Science and Technology
  • Volume:10 Issue:1
  • Effect of deformation on gamow-teller strength and electron capture cross-section for chromium isoto...

Effect of deformation on gamow-teller strength and electron capture cross-section for chromium isotopes

Authors : Asim Ullah, Muahmmad Riaz, Jameelun NABI, Mahmut BÖYÜKATA, Necla ÇAKMAK
Pages : 25-29
Doi:10.17678/beuscitech.640157
View : 19 | Download : 12
Publication Date : 2020-06-18
Article Type : Research Paper
Abstract :In this work, we explore the role of deformation parameter insert ignore into journalissuearticles values(β); on the calculated Gamow-Teller insert ignore into journalissuearticles values(GT); strength distributions and electron capture cross-sections insert ignore into journalissuearticles values(ECC); for 46,48,50 Cr isotopes within the formalism of the proton neutron-quasi-particle random phase approximation insert ignore into journalissuearticles values(pn-QRPA);. Three different β parameters were used in the present study. Two of them were calculated by using the interacting boson model insert ignore into journalissuearticles values(IBM); and the macroscopic-microscopic insert ignore into journalissuearticles values(Mac-mic); models. The third one is the experimental β values obtained by employing its relation with the experimental Binsert ignore into journalissuearticles values(E2);↑ values. The GT strength distributions were widely dispersed among all the daughter states of the given isotopes. They were found to have an inverse relation with the β parameter i.e decreasing with increasing the β value. The ECC was computed as a function of the β parameter and the results suggest that the calculated ECC decreased with decreasing value of the β for the selected cases.
Keywords : Gamow Teller, Electron capture cross section, pn QRPA

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025