IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Eurasian Journal of Biological and Chemical Sciences
  • Volume:3 Issue:1
  • Optimization of a chromatographic method for the quantification of polycylic aromatic hydrocarbons i...

Optimization of a chromatographic method for the quantification of polycylic aromatic hydrocarbons in drinking water samples

Authors : Selman KANDER, Belgin İZGİ
Pages : 10-14
View : 22 | Download : 16
Publication Date : 2020-06-22
Article Type : Research Paper
Abstract :Polycylic aromatic hydrocarbons negative effects are identified by various studies. Pre-processing methods to increase analysis and pre-analysis concentration of PAHs have great importance, especially in drinking water. In this study, in drinking water, EPA 550.1 method used for analyis of polycylic aromatic hydrocarbons in drinking water is aimed to reduce the amount and time by performing the amount of chemical and analysis time. According to recovery and repeatability parameters, results are obtained with evaluation compared with values in EPA method 550.1. Using a total of 70 ml chemical modified by method for six PAH parameters, the percentage recovery results are as follows; flour anthems %99,5, Benzoinsert ignore into journalissuearticles values(b);flouranthene %90,5, Benzoinsert ignore into journalissuearticles values(k);flouranthene %84,8, Benzoinsert ignore into journalissuearticles values(a);pyrene %91,1, Benzoinsert ignore into journalissuearticles values(g,h,i );perylene 75,9 and Indenoinsert ignore into journalissuearticles values(1,2,3-c,d);pyrene % 79,1.  Another concept that forms the basis of the SPE method, relative standard deviation of the percentage results for the same 6 PAH parameter are as follows; flouranthene % 12,8, Benzoinsert ignore into journalissuearticles values(b);flouranthene % 8,4, Benzoinsert ignore into journalissuearticles values(k);flouranthene %8,5, Benzoinsert ignore into journalissuearticles values(a);pyrene % 8,02, Benzoinsert ignore into journalissuearticles values(g,h,i);perylene % 12,2 and Indenoinsert ignore into journalissuearticles values(1,2,3-c,d);pyrene % 17,5. In the modified innovative methods, recovery and repeatability results are observed that analytically compatible to the values of the method EPA 550.1 .
Keywords : PAH, SPE, UHPLC, Drinking water

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025