IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • European Journal of Engineering and Applied Sciences
  • Cilt: 8 Sayı: 2
  • A Study of Preparation and Characterization of Crystal Violet Incorporated Polyacrylamide Gel (PAG) ...

A Study of Preparation and Characterization of Crystal Violet Incorporated Polyacrylamide Gel (PAG) Dosimeters

Authors : Betül Taşdelen, Ömer Faruk Güder
Pages : 99-104
Doi:10.55581/ejeas.1818279
View : 126 | Download : 204
Publication Date : 2025-12-31
Article Type : Research Paper
Abstract :Biomaterials and medical products intended for human contact undergo sterilization according to international standards. In biomedical applications, gamma radiation is the preferred sterilization method due to its superior properties. The applied dose of gamma radiation must be thoroughly validated to ensure patient safety and mitigate potential risks. Polymer gel dosimeters confirm whether a specified gamma sterilization dose is administered. In this study, a novel type of polymer gel dosimeter was developed, based on acrylamide with the addition of crystal violet dye. The doseimeters were irradiated with a 60Co gamma source at doses ranging from 7-28 kGy and at lower doses (30-90 mGy) for biomedical sterilization. FT-IR analyses were conducted for the purpose of structural characterization. Absorbance measurements were taken before and after irradiation using a a UV-Vis spectrophotometer to determine the dosimeter\\\'s dose response. Crystal violet (CV)-doped polyacrylamide gel (PAG) dosimeters have exhibited linear sensitivity to radiation dose. As the radiation dose increased, the dye\\\'s absorbance decreased, resulting in a lighter coloration of the solution. The stability of irradiated and non-irradiated dosimeters was measured at both room temperature and 4°C storage conditions over a 90-day period. The results indicated that the dosimeter exhibited stability under both environmental conditions. PAG dosimeters combined with CV additives show promise in validating dosing for sterilizing biomaterials and medical devices.
Keywords : Dozimetre, Kristal viyole, Gama radyasyon, PAG dozimetre, Sterilizasyon

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026