IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Hittite Journal of Science and Engineering
  • Volume:5 Special Issue
  • Investigation of Working Temperature Effect on Micro-Cogeneration Application of Proton Exchange Mem...

Investigation of Working Temperature Effect on Micro-Cogeneration Application of Proton Exchange Membrane Fuel Cells

Authors : Yağmur BUDAK, Ekin Özgirgin YAPICI, Yılser DEVRİM
Pages : 25-32
Doi:10.17350/HJSE19030000116
View : 31 | Download : 9
Publication Date : 2018-09-07
Article Type : Research Paper
Abstract :İn this study, micro-cogeneration application is used to increase the efficiency of Proton Exchange Membrane Fuel Cell PEMFC systems and effect of different operation temperatures on system performance is observed. For this reason, two different PEMFC systems were comparatively studied operating at 70o C and 160o C, respectively. Micro-cogeneration system design has done considering experimentally determined current density, power and temperature values. Since the amount of heat extracted from each PEMFC system is different related to the operating temperatures, different heat transfer fluids have been used for the cooling systems. These systems are designed for utilization of electricity and hot water for Atılım University Hydrogen Energy Laboratory. Heat loss calculation is made for the laboratory and thermal energy needed for heating the laboratory is calculated. Parallel to the design calculations, simple payback times for PEMFCs with micro-cogeneration applications were determined. LT-PEMFC and HT-PEMFC systems have 402 W and 456 W thermal powers respectively and 87.4 % and 92.8 % total cogeneration efficiencies were calculated for each system respectively. For each system maximum water temperatures and flow rates are calculated as a result of micro-cogeneration application. HT-PEMFC system has found to be capable of higher amount of heating. Even LT-PEMFC system has a lower thermal power and efficiency; it is determined to be more economical and has a lower pay pack time then HT-PEMFC system. For both systems, necessary number of stacks to be used for laboratory heating is calculated as four.
Keywords : Proton Exchange Membrane Fuel Cell, Micro cogeneration, Hydrogen energy

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026