IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Hittite Journal of Science and Engineering
  • Volume:4 Issue:2
  • Experimental Investigation of Cooling Performance a Heat Pump for Near Azeotropic Refrigerant R404A

Experimental Investigation of Cooling Performance a Heat Pump for Near Azeotropic Refrigerant R404A

Authors : Hayati TÖRE, Ali KİLİCARSLAN
Pages : 131-136
Doi:10.17350/HJSE19030000059
View : 18 | Download : 9
Publication Date : 2017-12-28
Article Type : Research Paper
Abstract :I n this study, in order to investigate the effect of outdoor air temperatures on the performance of an air source heat pump, operated in cooling mode, using R404A refrigerant, the heat pump was tested at the outdoor air temperatures ranging from 25 °C to 30 °C and a computer code was also developed by using Engineering Equation Solver EES . Experimental measurements have been carried out at the outdoor air temperatures ranging from 25 °C to 29 °C and they are repeated three times for better accuracy. The temperatures, the pressures, and the electric energy consumed by the compressor and the fans are measured by means of the K type thermocouple, bourdon type manometer and energy analyzer, respectively. Furthermore, an electric heater was installed in the room where the indoor unit was located and a humidifier is activated to provide the humidity conditions required for the room. The compressor pressure ratio, the power driven by the compressor, the heat rejection capacity of the outdoor unit, the cooling capacity of the indoor unit, the coefficient of performance of the heat pump COP were investigated according to different outdoor air temperatures. It was observed that as the outdoor air temperature increased, the indoor unit capacity and COP of the heat pump system decreased while the energy consumed by the compressor increased
Keywords : Heat pump, Cooling, Coefficient of performance, R404A

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.