  • Performance Analysis of Fresnel Lens Driven Hot Water/Steam Generator for Domestic and Industrial Us...

Performance Analysis of Fresnel Lens Driven Hot Water/Steam Generator for Domestic and Industrial Use: A CFD Research

Authors : Pinar Mert CUCE, Erdem CUCE
Pages : 1-9
Doi:10.17350/HJSE19030000285
View : 16 | Download : 8
Publication Date : 2023-03-31
Article Type : Research Paper
Abstract :In this study, the design, manufacture and thermal performance analysis of a Fresnel lens driven hot water/steam generator are presented. The designed system is suitable for domestic and industrial hot water/steam usage and can be easily scaled up to meet different capacity needs. In the first step of the research, thermal behaviour of the cast plate heat exchanger driven by a Fresnel lens with a concentration ratio of 100 is investigated at different working fluid velocities insert ignore into journalissuearticles values(0.6, 0.8, 1.0, 1.5 and 2.0 m/s); and at different absorber surface temperatures insert ignore into journalissuearticles values(700, 800, 900 and 1000 °C);. Outlet temperature of working fluid from the cast plate heat exchanger is determined through a 3D CFD model for each case. The capacity of the steam generator for different operating times insert ignore into journalissuearticles values(h = 1, 2 and 3 hours); is also evaluated. The highest working fluid temperature at the outlet of heat exchanger is 914.8 °C for T_cp= 1000 °C and V_wf = 0.6 m/s. On the other hand, the lowest temperature is observed as 424.7 °C for T_cp = 700 °C and V_wf = 2.0 m/s. The steam capacity of the system for h = 3 hours is determined as 1696.5 and 508.9 kg in the best insert ignore into journalissuearticles values(V_wf = 2.0 m/s); and worst cases insert ignore into journalissuearticles values(V_wf = 0.6 m/s);, respectively.
Keywords : Solar collector, Fresnel lens, Steam generator, Domestic hot water, Thermal performance

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.