  • The Effect of Wick Permeability and Porous Radius on Capillary and Entrainment Limit in A Heat Pipe ...

The Effect of Wick Permeability and Porous Radius on Capillary and Entrainment Limit in A Heat Pipe Reactor

Authors : Gizem Bakir
Pages : 279-285
Doi:10.17350/HJSE19030000317
View : 71 | Download : 62
Publication Date : 2023-12-31
Article Type : Research Paper
Abstract :For heat extraction in nuclear systems, interest in the design of nuclear reactors with heat pipes has increased. The determination of heat limitations is one of the remarkable factors for safety when heat pipes are used for nuclear systems. In this study, capillary and entrainment limit values for the heat pipe were calculated in a heat pipe reactor with potassium working fluid operating at 650 K. Five different effective porous radii (10.1x10-6, 10.225x10-6, 10.35x10-6, 10.425x10-6 and 10.6x10-6 m) and five different wick permeability (4.75x10-12, 5x10-12, 5.25x10-11, 5.5x10-12 and 5.75x10-12 m2) is considered for sintered copper wick heat pipe. While the effects of effective porosity radius, wick permeability, and wick radius on the capillary barrier were studied, only the effects of effective porosity radius were studied. While the effects of effective porosity radius, wick permeability, and wick radius on the capillary barrier are studied, only the effects of effective porosity radius are studied. The highest values of the capillary and entrainment limits are obtained when the porosity radius is 10.1x10-6 m. Besides, maximum capillary limits are achieved when the wick permeability is 5.75x10-12 m2 and the effective porosity radius is 10.1x10-6. This study aims to determine the optimum effective porous radius and wick permeability for this reactor and investigate the effect of effective porous radius and wick permeability on the heat pipe limitations.
Keywords : Heat pipe nuclear reactor, porous radius, wick permeability, wick radius, capillary limit, entrainment limit

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.