Investigation From Different Calculation Solutions In Vertebra Plans And The Reliability Of Different Dose Rate Dose

Authors : Yonca Yahşi ÇELEN, Hazım Orhan KIZILKAYA
Pages : 135-138
Doi:10.22399/ijcesen.597819
View : 20 | Download : 9
Publication Date : 2019-11-30
Article Type : Research Paper
Abstract :In this study, it was aimed to investigate the effect of different dose rate and different computational resolutions on stereotactic vertebrae irradiation with the results of the verification schemes on Gamma analysis and the effect on dose for critical organ and target volume. Ten patients with vertebrae participated in the study. Patients participating in the study were investigated for their effect on doses for critical organ and target volume by recalculating treatment plans at different dose rates and different computational resolutions without changing the optimization parameters using Intensity Modulated Radiation Therapy insert ignore into journalissuearticles values(IMRT); technique in the Eclipse treatment planning system with Varian Trilogy Linear Accelerator located in Şişli Hamidiye Etfal Training and Research Hospital , Radiation Oncology Department. Verification schedules of all the treatment plans The results were compared by using the Electronic Portal Imaging Device insert ignore into journalissuearticles values(EPID);. Using different dose rates did not affect our treatment planning accuracy. However, it was seen that the high resolution calculated plans represented the target and critical organ doses better.
Keywords : SBRT, IMRT, EPID, IGRT

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025