IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • International Journal of Energy Applications and Technologies
  • Volume:8 Issue:3
  • Numerical energy and exergy analysis of cooling systems: low GWP alternative refrigerants (R450A and...

Numerical energy and exergy analysis of cooling systems: low GWP alternative refrigerants (R450A and R1234ze) to R134a

Authors : Ragıp YILDIRIM, Kazım KUMAŞ, Ali Özhan AKYÜZ
Pages : 113-121
Doi:10.31593/ijeat.949316
View : 47 | Download : 14
Publication Date : 2021-09-30
Article Type : Research Paper
Abstract :The use of new generation refrigerants in heating and cooling systems operating according to vapor compression cycles and the preference of renewable energy sources is very important to reduce the negative effects on the environment. Here, the energy and exergy performance of refrigerant R450A and R1234ze, which are alternatives to R134a, were theoretically examined. Energy and exergy analysis of cooling system were performed under the same working conditions insert ignore into journalissuearticles values(source temperature is between -15 and 15 oC, and heat sink temperature is constant 30 oC);. The COP values of R134a, R1234ze, and R450A were 2.00, 1.98 and 1.97, respectively, while the heat source temperature was -15 oC. The heat source temperature was 15 oC, the COP values of R134a, R1234ze, and R450A were 4.82, 4.83 and 4.79, respectively. Under the given operating conditions, the highest total exergy destruction occurred at R134a, while the lowest total Exergy destruction occurred at R1234ze. The refrigerant with the highest and lowest cooling capacity was R134a and R1234ze. According to the results obtained from the analysis, it was concluded that R450A and R1234ze can be used instead of R134a.
Keywords : Global warming, New generation refrigerants, R134a R1234ze mixture, Energy and exergy

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.