IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • International Journal of Energy Studies
  • Volume:9 Issue:4
  • An experimental research on the effect of infrared and carbon fiber film heater integration in heat ...

An experimental research on the effect of infrared and carbon fiber film heater integration in heat pump food drying system on drying performance

Authors : Ümit İşkan, Ahmet Yüksel, Cüneyt Tunçkal
Pages : 601-618
Doi:10.58559/ijes.1540479
View : 15 | Download : 4
Publication Date : 2024-12-25
Article Type : Research Paper
Abstract :In this study, a closed-circuit heat pump food drying system was investigated by integrating a 50 W infrared lamp (IR) and a carbon fiber film heater (CFH) into the cabinet to dry 3 mm thick apple slices at 1 m/s air speed and 40℃ temperatures. The study aimed to investigate the differences in drying performance and energy consumption between a typical heat pump drying system (Scenario-I) and an IR and CFH supported heat pump drying system (Scenario-II). The results of the six-hour experiments conducted under laboratory conditions showed that the system reached a steady state 50% faster in Scenario-II and 41 g more moisture was extracted from the products. Furthermore, a 2% decrease in energy consumption and cost caused by the compressor was observed with IR and CFH support. The products that initially weighed 600 g were reduced to 200 g by 28% faster with 25% energy savings in Scenario-II. Finally, it was determined by thermal camera images that the products were dried homogeneously thanks to CFH. Therefore, it has been identified that IR and CFH supported HPD systems are preferable systems in terms of energy saving for low compressor load and fast drying processes.
Keywords : Heat pump drying, Carbon fiber film heater, Infrared, System performance

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025