IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Journal of Nuclear Sciences
  • Volume:4 Issue:2
  • Simulation of an anomalous behavior of thermoluminescence glow peak of quartz from Nigeria

Simulation of an anomalous behavior of thermoluminescence glow peak of quartz from Nigeria

Authors : EO Oniya, Oe OLUBİ
Pages : 50-57
View : 34 | Download : 13
Publication Date : 2018-11-12
Article Type : Research Paper
Abstract :Mechanism of the experimentally observed anomalous shift of a thermoluminescence insert ignore into journalissuearticles values(TL); glow peak that varied with irradiation dose is yet to be fully established. A theory that the anomalous peak must have contained more than one first order composite peak each with different TL dose characteristics has been one major explanation proposed to explain this observation. This work was undertaken to simulate the anomalous glow peak by using a modified version of a previously proposed model and numerically solving sets of simultaneous differential equations governing the stages of TL phenomena insert ignore into journalissuearticles values(excitation, relaxation and heating);. In the modified model, two additional electron trapping centers were incorporated in order to simulate accurately this glow curve. Computerized curve deconvolution insert ignore into journalissuearticles values(CGCD); analyses was carried out on the simulated   glow peak in attempt to retrieve back the electron trapping cente  r energies and to identify their respective peak positions. The outcome of this confirmed the peak to be possibly composite in nature comprising three overlapping glow peaks at 288, 300 and 317 o C with respective energy gaps of 1.70, 1.73 and 1.75eV. It is therefore further substantiated that this kind of temperature shift of peak with dose resulting from composite glow peaks is possible.
Keywords : simulation, anomalous glow peak, quartz, GCD analyses, thermoluminesence

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026