Influence of Voxel Size on Evaluation of Trabecular Bone Microstructure on Human Mandibles: A CBCT study

Authors : Ersen BİLGİLİ
Pages : 791-797
Doi:10.30621/jbachs.1037333
View : 22 | Download : 9
Publication Date : 2022-09-29
Article Type : Research Paper
Abstract :Purpose: This study aims to assess the effect of voxel size on trabecular microstructural evaluation onhuman cadaver mandiblesusing cone beam computed tomography insert ignore into journalissuearticles values(CBCT); images. Methods: Twenty two Volumes of Interest were obtained from to human cadaver mandibles which were scanned in three different voxel sizes using CBCT. Scanning performed in 0.125 mm insert ignore into journalissuearticles values(Group 1);, 0.2 mm insert ignore into journalissuearticles values(Group 2); and 0.3 mm insert ignore into journalissuearticles values(Group 3); voxel sizes. Regions of interest are calculated in both mandibles for both voxel sizes which are adjusted from apical third of all interdental alveolar trabecular bone from anterior and posterior mandible. Trabecular thickness insert ignore into journalissuearticles values(Tb. Th);; trabecular separation insert ignore into journalissuearticles values(Tb. Sp);; Bone Volume/Total Volume insert ignore into journalissuearticles values(BV/TV); values were obtained using plug in BoneJ of the software ImageJ. The results were evaluated statistically in software IBM SPSS Statistics 21. Results: Trabecular thickness and trabecular separation showed significant difference between first and the third and the second and the third groups insert ignore into journalissuearticles values(p=0.000);, while first and second group did not. BV/TV values showed no significant difference between whole groups. Conclusion: Beside microstructural analysis is not their first purpose CBCT images carry knowledge about trabecular bone microstructure could be a valuable bone quality assessment tool. High correlation between values with 0.125 mm and 0.2 mm and low correlation between values with 0.125 mm and 0.3 mm voxel sizes suggest that; this knowledge is clinically more valuable when voxel size is 0.2 mm or thinner.
Keywords : cone beam computed tomography, trabecular microstructure, voxel size

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025