IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Journal of Emergency Medicine Case Reports
  • Volume:10 Issue:2
  • Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pse...

Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report

Authors : Ozlem TALU KENDİR, Hayri Levent YILMAZ, Seyda Beğen DOĞANKOC, Sevcan BİLEN, Sinem SARI GOKAY, Mihriban Ozlem HERGUNER
Pages : 58-60
Doi:10.33706/jemcr.551140
View : 28 | Download : 15
Publication Date : 2019-04-01
Article Type : Other Papers
Abstract :Introduction:  The pseudo-tumor cerebri insert ignore into journalissuearticles values(PTC); is defined as the idiopathic or benign intracranial hypertension insert ignore into journalissuearticles values(IH);, complaints of which cannot be explained in a different way. PTC is an exclusion diagnosis, in which the neuroophtalmopathology of IH cannot be determined. The patients with PTC may have complaints such as headache, nausea, vomiting, temporary blurred vision, and mild-level vision loss or unilateral or bilateral abducens nerve paralysis may develop. The radiological examination of patients yields normal results. In case that IH develops due to any reason, the enlargement is seen in optic nerve sheath diameter insert ignore into journalissuearticles values(ONSD); in the acute period. Case reports: 14 year-old patient, who has been diagnosed for PTC in our unit, optic nerve sheath diameter insert ignore into journalissuearticles values(ONSD); measurement and follow-up of pressure change of whom have been performed by using ultrasonography insert ignore into journalissuearticles values(USG); method, is presented in order to discuss the contribution of this non-invasive method to diagnosis, treatment, and observation processes. Conclusion: USG and ONSD measurement in PTC cases may be effective and reliable monitoring method as much as invasive methods.
Keywords : Pseudo tumor Cerebri, Optic Nerve Sheath Diameter Measurement

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025