  • Volume:27 Issue:4
  • DÖKÜM KURONLARDA DİŞ KESİMİNİN TUTUCULUĞA ETKİSİ-EFFECTS OF TOOTH PREPARATION, ON RETENTION OF CAST ...

DÖKÜM KURONLARDA DİŞ KESİMİNİN TUTUCULUĞA ETKİSİ-EFFECTS OF TOOTH PREPARATION, ON RETENTION OF CAST CROWNS

Authors : Yasemin ARAS, Betül TUNCELLİ, Sabri ALTINTAŞ
Pages : 305-311
View : 18 | Download : 8
Publication Date : 2013-06-06
Article Type : Research Paper
Abstract :ÖZET Bu çalışmada, çeşitli derecelerde eğim gösteren döküm kuron preparasyonlarınm, uzunluk ve çaplarının değişgenli-ğine bağlı yeterli tutuculuk özellikleri araştırıldı. Maksimum tutuculuk özelliğinin elde edilebilmesi amacıyla değişen Özellikte toplam 60 adet diş preparasyon örnekleri paslanmaz çelikten hazırlandı. Bu örnekler üzerine hazırlanan kuron protezlerinin Cr-Ni alaşımından dökümleri yapıldı. 30 adet kuron protezlerinin içine kimyasal dağlama insert ignore into journalissuearticles values(etchİng); işlemi yapıldı. Tüm kuronlar paslanmaz çelikten hazırlanan diş örnekleri üzerine simante edildikten sonra, Instron Unıversal test cihazıyla çekme kuvveti ile dikey yönde uygulandı. Sonuçta dişin çapının artması, buna karşılık eğimin azalması ile tutuculuğun arttığı gözlendi. Ancak 14 derece eğimli diş preparasyonu üzerine hazırlanan kuronların kimyasal dağlama insert ignore into journalissuearticles values(etching); yapılmasıyla tutuculuk özelliklerinden anlamlı bir farklılık görülmedi. Anahtar sözcükler: Tutuculuk, diş kesimi, döküm kuron. ABSTRACT In this study various degrees of occlusal convergence, which taken into consideration the length and diameter of cast crown preparations, was designed to obtain adequate resistance form. In order to test the validity of the resistance form, six groups of stainless steel dies were prepared. The crowns were prepared and casted with Cr-Ni alloy. 30 of this specimens were chemically etched and then cemented. Retention strength of each crown was tested in tension zones using an instron testing machine, the results for each test group were listed in tables. Increase in tooth diameter and decrease in convergence degree result in retention increase on the other hand increase in etched crown retention was noticed. But retention of prepared etched crowns with an angle of 14 degree has not shown a significant difference. Key words: Retention, tooth preparation, cast crowns.
Keywords :

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.