IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Journal of the Turkish Chemical Society Section A: Chemistry
  • Volume:7 Issue:3
  • Stability indicating analytical method development and validation of eltrombopag olamine in tablet d...

Stability indicating analytical method development and validation of eltrombopag olamine in tablet dosage form by RP-UPLC

Authors : Ajay I PATEL, Shweta GOSAI, Kajal JADAV, Amit J VYAS, Ashok B PATEL, Nilesh K PATEL
Pages : 845-850
Doi:10.18596/jotcsa.724484
View : 56 | Download : 10
Publication Date : 2020-10-30
Article Type : Research Paper
Abstract :A simple, precise and accurate stability indicating isocratic Reverse Phase Ultra-Performance Liquid Chromatographic insert ignore into journalissuearticles values(RP-UPLC); method was developed for quantitative determination of Eltrombopag olamine in the presence of degradant products. The method was developed using Acquity UPLC BEH C18 insert ignore into journalissuearticles values(50 × 2.1 mm, 1.7 μm); column with mobile phase containing a mixture of water insert ignore into journalissuearticles values(pH 3 with 30 % formic acid); and acetonitrile in ratio 30:70. The eluted compound was monitored at 244 nm and run time was within 2 min. Eltrombopag olamine was subjected to the stress condition of oxidative, acid, base, thermal and photolytic degradation. The drug was found to degrade significantly in acid, base and oxidative stress condition and stable in thermal and photolytic degradation condition. The degradation products were well resolved from main peak, providing stability indicating power of the method. The developed method was validated as per ICH Q2insert ignore into journalissuearticles values(R1); guideline with Linearity range was between 25-75 μg/ml, % Recovery range was found as 99.8-101.9 and Precision was found as RSD less than 2.
Keywords : Eltrombopag olamine, ultra performace high liquid chromatography, stability indicating, force degradtion, validation

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.