IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Journal of the Turkish Chemical Society Section A: Chemistry
  • Volume:11 Issue:1
  • Voltammetric performance of nanofiber structured over-oxidized poly(3,4-ethylenedioxythiophene) modi...

Voltammetric performance of nanofiber structured over-oxidized poly(3,4-ethylenedioxythiophene) modified pencil graphite electrodes for dobutamine sensing

Authors : Ayşegül Özbek, Levent Özcan
Pages : 55-70
Doi:10.18596/jotcsa.1306564
View : 71 | Download : 118
Publication Date : 2024-02-04
Article Type : Research Paper
Abstract :A modified electrode was developed for the electrochemical sensing of dobutamine (DBT), one of the catecholamines. For this modification process, pencil graphite electrodes (PGE) were modified with over-oxidized nanofiber structured poly (3,4-ethylenedioxythiophene) (PGE/OPEDOTNF) by electropolymerization. The electrochemical performance of PGE/OPEDOTNF was evaluated by cyclic and differential pulse voltammetry. In addition, the performances of non-nanofiber PEDOT-modified PGE electrodes were also examined for comparison. The characterization of the modified electrodes was carried out by scanning electron microscopy and electrochemical methods. The signal of the modified electrodes was observed in a linear range of 0.1-2.0 µM against DBT using the differential pulse voltammetry method. The limit of detection and quantification are calculated as 0.026 µM and 0.086 µM, respectively. The effect of the interfering species was examined. It has been shown that DBT can be detected sensitively and selectively using pencil graphite electrodes modified with nanofiber-structured poly(3,4-ethylenedioxythiophene). The repeatability of PGE/OPEDOTNF electrodes was found to be 5.2%. PGE/OPEDOTNF electrodes remained stable for 15 days without losing their electrochemical activity.
Keywords : Dobutamine, electrochemical sensing, modified electrode, poly 3, 4ethylenedioxythiophene, nanofiber structure, pencil graphite electrode

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025