IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi
  • Volume:28 Issue:4
  • FARKLI ZAMAN PERİYOTLARI İLE UYGULANAN GECE KORUYUCULU VİTAL BEYAZLATMA AJANININ GİOMER RESTORATİFLE...

FARKLI ZAMAN PERİYOTLARI İLE UYGULANAN GECE KORUYUCULU VİTAL BEYAZLATMA AJANININ GİOMER RESTORATİFLERİN YÜZEY PÜRÜZLÜLÜĞÜ ÜZERİNE ETKİSİ

Authors : Dilan KARA, Neslihan TEKÇE, Aslıhan KOÇAK, Emre ÖZEL
Pages : 462-468
Doi:10.17567/ataunidfd.473719
View : 46 | Download : 13
Publication Date : 2018-10-14
Article Type : Research Paper
Abstract :Amaç: Bu çalışmanın amacı, farklı zaman periyotları ile uygulanan gece koruyuculu beyazlatma ajanının üç posterior restoratif materyalin yüzey pürüzlülüğü üzerine etkisini incelemektir Gereç ve Yöntem: Üç farklı tipte posterior restoratif materyalden [ Beautifil-Bulk Restorative (giomer bulk-fill), Beautifil II (giomer posterior) ve Aelite LS Poste - rior (hibrit kompozit rezin) ] toplam 90 adet kompozit rezin (disk örneği (8 mm çapında, 2 mm kalınlıkta) hazırlanmıştır (n=30). Her bir materyal %16 karbamid peroksit ağartma maddesi içeren Opalescence PF’nin disklere uygulama prosedürlerine göre üç alt gruba ayrılmıştır (n=10). Grup-1: başlangıç ölçümleri; Grup-2: 7 gün boyunca günde 4 saat %16 Opalescence PF uygulaması; Grup-3: 7 gün boyunca günde 6 saat % 16 Opalescence PF uygulaması. Grupların yüzey pürüz - lülük ölçümleri 24 saat ve 1 hafta sonunda profilo - metre (Ra, m m) ile yapılmıştır. Veriler, iki yönlü var - yans analizi (ANOVA ) ve Tukey's HSD post-hoc testi ile istatistiksel olarak analiz edilmiştir (p<0.05). Bulgular: Başlangıç zaman diliminde, Aelite LS Poste- rior (0.87 Ra), Beautifil-Bulk Restorative (0.70 Ra) ve Beautifil II (0.65 Ra) materyallerinin yüzey pürüzlülük değerleri istatistiksel olarak benzer bulunmuştur (p > 0.05). Grup-2 ve Grup-3'te de bu üç materyalin yü- zey pürüzlülük değerleri benzerdir. Fakat, Beautifil II’ye 7 gün boyunca 6 saat %16 Opalescence PF uygulaması sonrasında yüzey pürüzlülüğü önemli düzeyde artmıştır (0.65 Ra’dan 0.95 Ra’ya) (p < 0.05). Sonuç: Beautifil-Bulk Restorative ve Aelite LS Posterior, uygulanan test periyotları boyunca yüzey pürüzlülük değişimlerine karşı stabildir. Fakat, Beautifil II’nin %16 Opalescence PF’nin bir hafta boyunca günde 6 saat uygulanmasından sonra yüzey pürüzlülük değerleri ciddi oranda artmıştır. Anahtar Kelimeler: Beyazlatma, giomer THE EFFECT OF NIGHT-GUARD VITAL BLEACHING AGENT WITH DIFFERENT TIMING PERIODS ON SURFACE ROUGHNESS OF GIOMER RESTORATIVES Aim: The aim of this study was to examine the effect of night-guard vital bleaching agent with different timing periods on the surface roughness of three posterior restoratives. Material and Methods: A total of 90 composite resin disc specimens (8 mm in diameter, 2 mm in thickness) were prepared from three different types of restoratives [ Beautifil-Bulk Restorative (giomer bulk-fill), Beautifil II (giomer posterior) ve Aelite LS Posterior (hybrid resin composite) ] (n=30). Each group was divided into three subgroups according to application procedures of 16% carbamide peroxide Opalescence PF bleaching agent (n=10). Group-1: baseline measurements; Group-2: 4 hours/day for 7-day ; Group-3: 6 hours/day for 7-day. Measurements were conducted at 24-h and 1 week using a profilometer (Ra, m m). The values were statistically analysed with two ANOVA and Tukey’s HSD post-hoc test (p<0,05). Results: At baseline, surface roughness values of Aelite LS Posterior (0.87 Ra), Beautifil-Bulk Restorative (0.70 Ra) and Beautifil II (0.65 Ra) were found statistically similar (p > 0.05). Surface roughness values of these three materials also were found statistically similar for Group-2 and Group-3. However, the values increased significantly for Beautifil II (0.65 Ra to 0.95 Ra) after bleaching agent application for 6 hours per day along 7-day (p<0.05). Conclusion: Beautifil-Bulk Restorative and Aelite LS Posterior are durable against surface roughness changes in the following test periods. However, surface roughness values of Beautifil II increase significantly after using 16% Opalescence PF 6 hours per day for one week. Keywords: Bleaching, giomer, surface roughness
Keywords : Beyazlatma, giomer

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026