IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi
  • Volume:28 Issue:4
  • GÜMÜŞ ZEOLİT İLAVE EDİLEN AKRİLİK REZİNLERİN EĞİLME DAYANIMLARININ İN-VİTRO DEĞERLENDİRİLMESİ...

GÜMÜŞ ZEOLİT İLAVE EDİLEN AKRİLİK REZİNLERİN EĞİLME DAYANIMLARININ İN-VİTRO DEĞERLENDİRİLMESİ

Authors : Sema MURAT
Pages : 539-544
Doi:10.17567/ataunidfd.473930
View : 56 | Download : 14
Publication Date : 2018-10-14
Article Type : Research Paper
Abstract :Amaç: Bu çalışmanın amacı, antimikrobiyal ajan olarak farklı ağırlık yüzdeleriyle ilave edilen gümüş-zeolitin ısıyla polymerize olan polimetilmetakrilat protez kaidesinin eğilme dayanımına etkisinin ısıl işlem öncesi ve sonrası değerlendirilmesidir.   Gereç ve Yöntem: 64x10x3,3mm ebatlarında standart test örnekleri gümüş-zeolitin (Zeomic @ ) % 0, % 0,5, % 2 ve % 4 kuru ağırlık yüzdelerinde ısı ile polimerize olan akrilik tozuna ilave edilmesiyle hazırlanmıştır. Her grup için toplam 20 örnek hazırlanmıştır. Kontrol grubu olarak gümüş-zeolit ilave edilmeyen örnekler kullanılmıştır (n=20). Bu gruplar daha sonra ısıl işlem uygulanmayan ve uygulanan olmak üzere 2 alt gruba (n=10) daha ayrılmıştır. Isıl döngü uygulanan gruptaki örnekler 10000 döngülük ısıl döngü işlemine (5 °C ve 55 °C’de, 30 sn aralıkla) tabii tutulmuşlardır. Eğilme dayanımlarının hesaplanmasında universal test cihazında 3 nokta eğme testi yapılmıştır. Verilerin istatistiksel analizi için Minitab Release 15 yazılım programı ile ANOVA ve bağımlı örneklem t-testi kullanılmıştır. Anlamlılık p<0.05 düzeyinde değerlendirilmiştir. Bulgular: Isıl döngü işlemi uygulanmayan ve uygulanan grupların her ikisinde de; kontrol grubu (% 0 ağırlık yüzdesi) diğer üç gruptan istatistiksel olarak anlamlı şekilde daha yüksek eğilme dayanımı gösterirken, ağırlık yüzdesi arttıkça (% 0,5, % 2, % 4) eğilme dayanımı azalmıştır (p<0.05). Bütün gruplar arasındaki farklılık istatistiksel olarak anlamlı bulunmuştur (p>0.05). Ayrıca ısıl döngü işlemi bütün gruplarda eğilme dayanımını istatistiksel olarak anlamlı şekilde azaltmıştır (p<0.05). Sonuç: Çalışmamızda gümüş-zeolitin ağırlık yüzdesinin artması ve ısıl döngü işlemi uygulanması ile eğilme dayanımının azalmasına rağmen bulunan değerler ISO 20795-1:2013(E) no’lu standartta belirtilen 65 MPa’ dan daha yüksek bulunmuştur. Anahtar Kelimeler: Akrilik, Eğilme dayanımı, Gümüş-zeolit, Isıl döngü işlemi IN-VITRO EVALUATION OF FLEXURAL STRENGTHS OF ACRYLIC RESINS INCORPORATED SILVER ZEOLITE ABSTRACT Aim:   The aim of this study was to evaluate the effect of silver-zeolite on flexural strength, which was added into heat polymerized polymethylmethacrylate (PMMA) denture base resin with different percentages as antimicrobial agent before and after thermal cycling. Material and method: Standard test specimens in sizes of 64x10x3.3 mm were prepared by adding silver-zeolite (Zeomic @ ) into heat polymerized acrylic powder with 0 %, 0.5 %, 2 %, and 4 % dry weight percentages. A total of 20 samples were prepared for each group. A total of 20 samples without silver-zeolite served as the control group. These groups were then divided into 2 subgroups (n = 10), a not-thermal cycled and thermal cycled group. Samples in thermal cycled group were subjected to 10000 thermal cycling (5 °C-55 °C). Three-point FS of the specimens was tested in a universal testing machine and the flexural strength data (σ) was calculated (MPa). Statistical analysis of the data was performed using the Minitab Release 15 software program by ANOVA and paired t-test. Significance was set at p<0.05. Results: For both groups (non-thermal cycled and thermal cycled), the flexural strength of the control group (0% weight percentage) was significantly higher than the other three groups (0.5 %, 2 %, 4 %) (p<0.05). The differences between other 3 groups were also statistically significant (p<0.05). In addition, for all groups the flexural strength decreased statistically significantly with thermal cycling (p<0.05). Conclusion: Although an increase in the percentage of silver-zeolite and the application of thermal cycling reduced the flexural strength, our results are still higher than the 65 MPa which is specified in the standard ISO 20795-1: 2013 (E). Keywords: Acrylic, Flexural strength, Silver-zeolite, Thermal cycling
Keywords : Akrilik, Eğilme dayanımı, Gümüş zeolit

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026