IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • MANAS Journal of Engineering
  • Volume:11 Issue:2
  • Preconcentration and determination of Cu(II) and Cd(II) ions from wastewaters by using hazelnut shel...

Preconcentration and determination of Cu(II) and Cd(II) ions from wastewaters by using hazelnut shell biosorbent immobilized on Amberlite XAD-4 resin

Authors : Ibrahim Teğin, Selma Akdeniz, Ihsan Alacabey, Kadir Erol, Orhan Acar
Pages : 177-189
Doi:10.51354/mjen.1260477
View : 102 | Download : 84
Publication Date : 2023-12-25
Article Type : Research Paper
Abstract :Hazelnut shell biosorbent immobilized on Amberlite XAD-4 polymer resin as solid phase extraction method was developed and used for preconcentration of Cu(II) and Cd(II) ions from aqueous solutions. Concentrations of analytes in solutions were determined by Flame Atomic Absorption Spectrometry after extraction with column technique. Functional groups of nutshell biosorbent immobilized on resin were characterized by Fourier transform infrared spectrometry. Optimized critical parameters for preconcentration of Cu2+ and Cd2+ ions from sample solutions with nutshell immobilized on the resin were the pH value of solution, type of eluent solutions, the flow rate of sample solution, quantities of nutshell biosorbent, Amberlite XAD-4 resin, and enrichment factors, respectively. Detection limits of Cu2+ and Cd2+ ions found were 0.29 μg L-1 and 0.25 μg L-1, respectively. The method proposed was applied for determinations of Cu2+ and Cd2+ ions in standard reference material (BCR-670 aquatic plant sample) for accuracy and applied to real water samples such as wastewater and Van lake water. At the 95% confidence level, relative standard deviations (RSDs) were found as 1.44% for Cd2+ and 1.21% for Cu2+ ions with three replicate measurements.
Keywords : amberlite XAD 4, hazelnut shell, preconcentration, trace element, wastewater

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025