IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Middle Black Sea Journal of Health Science
  • Volume:6 Issue:1
  • Influence of reciprocating NiTi instruments on the accuracy of apex locator integrated endomotors du...

Influence of reciprocating NiTi instruments on the accuracy of apex locator integrated endomotors during simultaneous working length determination

Authors : Öznur SARIYILMAZ, Evren SARIYILMAZ, Cangül KESKİN
Pages : 70-75
Doi:10.19127/mbsjohs.701606
View : 74 | Download : 20
Publication Date : 2020-04-30
Article Type : Research Paper
Abstract :Objective: To compare simultaneous working length determination efficiency and electrical resistance of thermally treated NiTi files and their counterfeits. Methods: Access cavities were prepared for sixty human mandibular premolar teeth, which were then numbered with a marker. Actual working length was determined visually by introducing a #10 K-file into the root canal and the reference point was marked for further steps. By using flowable composite, the teeth were fixed at the cementoenamel junction to a hole in the center of a glass bottle cap and a second hole prepared on it for lip clip. Alginate impression material was filled into glass bottle then the tooth was embedded into it. Experimental models randomly divided into 6 groups as Group WOG insert ignore into journalissuearticles values(WaveOne Gold);, Group WO insert ignore into journalissuearticles values(WaveOne);, Group W+ insert ignore into journalissuearticles values(Superline W+);, Group RB insert ignore into journalissuearticles values(Reciproc Blue);, Group R insert ignore into journalissuearticles values(Reciproc);, Group V insert ignore into journalissuearticles values(Superline V);. Root canals were prepared until the endomotor stopped when reaching the apical foramen and the silicon stopper was moved to the previously marked reference point to determine the simultaneous working length. The electrical resistance of the files insert ignore into journalissuearticles values(from tip of file to notch of the shaft); was measured using a multimeter. Results: No readings could be obtained via apex locator for Group V. Group W+ was significantly less accurate compered the other groups insert ignore into journalissuearticles values(p<0.05);. No significant difference was found among the groups WO, WOG, R, and RB insert ignore into journalissuearticles values(p>0.05);. Conclusion: Thermal treatments of NiTi alloys had no effect on the accuracy of simultaneous working length determination. However, Counterfeit endodontic files failed to show of accurate simultaneous working length determination.
Keywords : Electrical resistance, Endodontics, Nitinol, Root Canal Preparation

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026