IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Mugla Journal of Science and Technology
  • Cilt: 11 Sayı: 2
  • INVESTIGATION OF PEROXIDASE-MIMICKING PROPERTIES OF FeNiCo METAL-ORGANIC FRAMEWORK DECORATED MWCNT C...

INVESTIGATION OF PEROXIDASE-MIMICKING PROPERTIES OF FeNiCo METAL-ORGANIC FRAMEWORK DECORATED MWCNT COMPOSITE NANOMATERIAL

Authors : Yudum Tepeli Büyüksünetçi
Pages : 1-9
Doi:10.22531/muglajsci.1687954
View : 96 | Download : 153
Publication Date : 2025-12-31
Article Type : Research Paper
Abstract :Enzyme-mimicking materials replicate natural enzyme functions, offering more durable, cost-effective, and eco-friendly alternatives, making them important for biotechnology and industrial applications. In this study, the peroxidase like properties of a FeNiCo metal-organic framework-decorated multi-walled carbon nanotube (FeNiCo MOF-MWCNT) composite nanomaterial were investigated for the first time. The nanocomposite was synthesized and characterized using Scanning Electron Microscopy (SEM), SEM-Mapping, SEM-EDS, XRD, and FT-IR techniques. Its enzyme-mimicking activity was evaluated using a colorimetric, non-enzymatic H₂O₂ biosensor with 3,3\\\',5,5\\\'-Tetramethylbenzidine (TMB) as the substrate. The biosensor comprises optimized amounts of FeNiCo MOF-MWCNT and TMB. Upon H₂O₂ addition, the nanocomposite mimics peroxidase activity by reducing H₂O₂ to H₂O, while oxidizing TMB to its blue-colored form, TMB(ox), showing absorbance at 654 nm. After optimizing conditions, the biosensor exhibited a linear response to H₂O₂ concentrations ranging from 0.1 mM to 12 mM. It also demonstrated high selectivity, with negligible interference from substances like KCl, ascorbic acid, urea, and NaCl. Accuracy tests using commercial H₂O₂ disinfectant showed results between 100% and 103%, confirming the biosensor\\\'s reliability for practical applications.
Keywords : Metal organik çerçeveler, enzim taklit, enzimsiz H2O2 biyosensörü, kolorimetrik biyosensör

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026