IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Natural and Applied Sciences Journal
  • Volume:3 Issue:Special Issue:Full Papers of 2nd International Congress of Updates in Biomedical Engineering
  • Magnetic Resonance Imaging Compatible Biomaterials For Realization of Interventional Operations

Magnetic Resonance Imaging Compatible Biomaterials For Realization of Interventional Operations

Authors : Seval UĞURLU, Engin BAYSOY, Mustafa KOCAKULAK
Pages : 94-101
View : 95 | Download : 16
Publication Date : 2021-01-13
Article Type : Research Paper
Abstract :Realization of interventional therapeutic procedures with guidance of Magnetic Resonance Imaging insert ignore into journalissuearticles values(MRI); is a promising novelty in area of interventional surgery because of eliminating x-ray exposure to patient body. Together with radiation free nature, advances in MRI techniques present superior soft tissue contrast and real time physiologic parameters from related tissue. However, the strong static magnetic field, magnetic radiofrequency insert ignore into journalissuearticles values(RF); pulses, and time-varying gradient fields applied during MRI, may result in exceeded heating risk over interventional instruments and adjacent tissue inside patient body. Additionally, since real time tracking and determination of device position inside patient body is critical for operators, sufficient visibility under MRI is another challenging issue to overcome. Therefore, proper biomaterials must be utilized for designing and development of MRI compatible interventional instruments by considering many factors including biocompatibility, MRI safety, MRI visibility, and other mechanical needing.
Keywords : Magnetic Resonance Imaging, MRI Compatible Biomaterials, Biocompatibility, MRI Safety, Nanoparticles

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026