Journal article

The Effects on Drawdown in Well Water Level for Nominal Diameters of the Deep Well Irrigation Pumps

Abstract

In this study, the effects on drops insert ignore into journalissuearticles values(drawdown); in water level for three different nominal diameters of the irrigation pumps which are vertical line shaft and submersible deep-well pumps in the well having a fixed hardware are investigated. The experiments based on the Anonymous insert ignore into journalissuearticles values(2002); standard having the conditions of fixed well and stationary hydraulic well-load are done at the test tower of deep-well pump in the department of Agricultural Machinery and Technology Engineering at the Selcuk University. The test tower works on the principle of open-hydraulic circuit composite containers. According to the results, flow-rate of pump and the level of drops in well are increased by the increment on the nominal diameter of the pump. For deep-well pump of vertical line shaft, a linear relationship between the nominal diameter of the pump and drops in well is not found under the constant flow-rate. For submersible deep-well pumps and the constant flow-rate insert ignore into journalissuearticles values(70 m3 h-1);, the level of drops in well are decreased by the increment on the nominal diameter of the pump. Submersible deep-well pumps have larger level of drops in well than vertical line shaft deep-well pumps under the constant flow-rate.

Keywords

Milli derin kuyu pompasıDalgıç pompaPompa işletme karakteristikleriPompa anma çapıKuyu su seviyesindeki düşümSulama pompaları

63 views · 34 downloads