IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Turkish Journal of Analytical Chemistry
  • Volume:3 Issue:2
  • Synthesis and analytical applications of thiosemicarbazide derivative

Synthesis and analytical applications of thiosemicarbazide derivative

Authors : Abidin GÜMRÜKÇÜOĞLU, Olcay BEKİRCAN
Pages : 59-63
Doi:10.51435/turkjac.1030232
View : 23 | Download : 7
Publication Date : 2021-12-30
Article Type : Research Paper
Abstract :1-insert ignore into journalissuearticles values(4-tert-butylphenyl);4-insert ignore into journalissuearticles values(4-trifluoromethylphenyl);carbonylthiosemicarbazide insert ignore into journalissuearticles values(OBS); and was synthesized by reaction of 4-tert-Butylbenzoic hydrazide with 4-insert ignore into journalissuearticles values(trifluoromethyl);phenylisothiocyanate. The influence of many metal cations on the spectroscopic properties of the synthesized compound was investigated in dmso-water insert ignore into journalissuearticles values(1:1); by means of emission spectrometry.The influence of a series of metal ions including Cu2+,Co2+ , Al3+,Cr3+,Fe3+, Pb2+, Ni2+, Cd2+, Zn2+,Ag+ , Ba2+ , Mo3+, Se,Ca2+,Sn4+,Sb3+,Na+, K+,Li+,Sc3+, Sr2+, As3+, Be2+ and Mg2+on the spectroscopic properties of the ligand was investigated by means of emission spectrometry.The compounds were selectively complexed with Fe3+among many metal ions. The complex stoichiometry and the stability constant were determined by fluorimetric measurements. The ligand having thiosemicarbazide insert ignore into journalissuearticles values(OBS); showed sensitivity for Fe3+ ion with a linear range between 0.5 and 5.5 mg/L. The new method was applied in the determination of iron in the the sandy-soil reference material. A modified Standard addition method was used to remove the matrix effect.Detection and quantification limits were 0.07 and 0.214 mg/L, respectively.The simple and cost-effective method can be applied to soil samples.
Keywords : Thiosemicarbazides, Fe3, Fluorescence measurements, complex stoichiometry

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025