IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Akademik Gıda
  • Volume:22 Issue:3
  • Effect of Cold PlasmaTreatment on Physicochemical and Microbiological Properties of Clotted Cream

Effect of Cold PlasmaTreatment on Physicochemical and Microbiological Properties of Clotted Cream

Authors : Gökhan Akarca, Betül Özkan, Azize Atik, İlker Atik
Pages : 195-204
Doi:10.24323/akademik-gida.1603756
View : 13 | Download : 11
Publication Date : 2024-12-18
Article Type : Research Paper
Abstract :The aim of this study was to determine the effect of cold plasma treatment, which was applied by using two different gases (O2 and Ar) and their mixtures onto sample surfaces for different intervals, on the physicochemical and microbial parameters of clotted cream during storage for up to 10 days. Cold plasma treatment caused a decrease in pH, aw, L*, and b* values of clotted cream samples and an increase in their a* and TBA values. The pH values of samples ranged from 4.68 to 6.67, and the range for aw values was between 0.903 and 0.803. For TBA, the highest change was observed in the K2 sample with 0.479 mg malondialdehyde/kg. The color L* values of all samples were between 99.79 and 93.82, a* values between 1.82 and 1.22, and b* values between 6.22 and 4.74. Among the treatments, the treatment of O2-Ar gas mixture (50-50%) resulted in the highest decrease in the total counts of aerobic mesophilic bacteria (TMAB), total aerobic psychrophilic bacteria, proteolytic bacteria, yeast-molds, coliform group bacteria, and Staphylococcus aureus. Compared to the control sample, at the end of 10 days of storage, a decrease of 2.41 for TMAB, 3.64 for total yeast-mold, 4.23 for coliform group bacteria, and 4.72 log cfu/g for S. aureus was achieved. Results indicated that the cold plasma treatment did not cause significant changes in the physicochemical values of clotted cream samples but reduced their microbial load.
Keywords : Soğuk plazma, Kaymak, Argon, Patojen, Kalite

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025