IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Clinical and Experimental Health Sciences
  • Volume:12 Issue:3
  • Comparison of the Effect of Denture Cleansers on Long-Term Water Sorption and Solubility of Polyethe...

Comparison of the Effect of Denture Cleansers on Long-Term Water Sorption and Solubility of Polyetheretherketone with other Denture Base Materials

Authors : Fatih DEMİRCİ, Abdulsamet TANIK
Pages : 672-677
Doi:10.33808/clinexphealthsci.1011897
View : 30 | Download : 18
Publication Date : 2022-09-28
Article Type : Research Paper
Abstract :Objective: In this in vitro study, the effect of three denture cleansers insert ignore into journalissuearticles values(DCs); after immersion in a chemical solution applied to polyetheretherketone insert ignore into journalissuearticles values(PEEK); and other denture base materials insert ignore into journalissuearticles values(DBMs); on long-term water sorption and solubility was compared. Methods: Disk-shaped specimens insert ignore into journalissuearticles values(50±1.0-mm diameter and 0.5±0.1-mm thickness); were prepared from four DBMs insert ignore into journalissuearticles values(n=48);. All specimens were randomly subdivided into four storage media groups insert ignore into journalissuearticles values(n=12);: Corega tablet insert ignore into journalissuearticles values(CT);, Protefix tablet insert ignore into journalissuearticles values(PT);, 1% sodium hypochlorite insert ignore into journalissuearticles values(NaOCl); solution insert ignore into journalissuearticles values(SH);, and control insert ignore into journalissuearticles values(distilled water, DW);. Storage media were renewed thrice a day for 120 days and simulated for 1-year use of overnight immersion. Water sorption and solubility insert ignore into journalissuearticles values(µg/mm3); of DBMs before and after immersion in storage media were examined and obtained data were statistically analyzed using a multivariate analysis of variance, followed by multiple comparisons by a posthoc Tukey’s test insert ignore into journalissuearticles values(p 0.05);. Conclusion: DCs affect PEEK and other DBMs in terms of water sorption and solubility in the long-term follow-up.
Keywords : Denture base material, denture cleanser, PEEK, Solubility, water sorption

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025