IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Current Research in Dental Sciences
  • Volume:28 Issue:4
  • SİLİKON ESASLI YUMUŞAK ASTAR MATERYALLERİNDE BEKLETME SÜRELERİNİN SERTLİK VE SU EMİLİMİ ÜZERİNE ETKİ...

SİLİKON ESASLI YUMUŞAK ASTAR MATERYALLERİNDE BEKLETME SÜRELERİNİN SERTLİK VE SU EMİLİMİ ÜZERİNE ETKİSİ

Authors : Faik TUĞUT, Memre COŞKUN, Türker AKAR
Pages : 469-474
Doi:10.17567/ataunidfd.473726
View : 25 | Download : 9
Publication Date : 2018-10-14
Article Type : Research Paper
Abstract :Amaç: Bu çalışmanın amacı, silikon esaslı yumuşak astar materyalinin su içerisinde bekletme sürelerinin maddenin sertliği ve su emilimi üzerine etkisini araştırmaktır. Gereç ve Yöntem: Çalışmada s ilikon esaslı yumuşak astar maddesi Permaflex ve aynı maddenin izobutil- metakrilat likit ilave edilmiş formu kullanıldı. Yumuşak astar materyalleri üretici talimatlarına uygun olarak su emilimi testleri için insert ignore into journalissuearticles values(10x10x1mm); boyutlarında, sertlik testleri için ise insert ignore into journalissuearticles values(10x10mm); boyutlarında h azırlandı ve 37 0 C’lik su banyosu içerisinde bekletildi . 1. gün, 1. hafta, 1,3 ve 6 aylık süre zarflarında su emilim ve Shore A sertlik değerleri ölçümleri gerçekleştirildi. Veriler Man Whitney U testi, Friedman testi ve Wilcoxon testi kullanılarak belirlendi insert ignore into journalissuearticles values( α =0.05);. Bulgular: Sertlik değerleri bakımından, Permaflex ve Permaflex+izobutilmetakrilat grupları arasında tüm za- man dilimleri kıyaslandığında istatistiksel olarak anlamlı fark tespit edilmiştir insert ignore into journalissuearticles values(p<0,05);. Su emilim değerleri ara- sında da sadece 3. ay ölçümlerinde istatistiksel olarak fark tespit edilmiştir insert ignore into journalissuearticles values(p<0,05);. Permaflex grubunun su emilim değeri Permaflex+izobutilmetakrilat grubundan istatistiksel olarak anlamlı derecede yüksek olarak tespit edilirken daha düşük sertlik değerine sahip olduğu bulunmuştur. Suda bekletilme süreleri boyunca hem Permaflex hem de Permaflex+izobutilmetakrilat gruplarının su emilim değerlerinde artış görülürken, sertlik değerlerinde istatistiksel olarak önemli bir artış tespit edilmemiştir. Sonuç: İzobutilmetakrilat’ın ve farklı zaman dilimlerin- de bekletmenin sertlik ve su emilimi açısından yumu- şak astar maddesi üzerinde değişikliğe sebep olduğu belirlendi. * Cumhuriyet Üniversitesi, Dişhekimliği Fakültesi, Protetik Diş Tedavisi AD, Sivas ** Erzincan Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi AD, Erzincan     Anahtar Kelimeler: Yumuşak astar maddesi, izobutilmetakrilat, sertlik, su emilimi THE EFFECT OF STORAGE TIMES ON THE HARDNESS AND WATER SORPTION IN SILICONE-BASED SOFT LINING MATERIALS Aim: The purpose of this research is to investigate the effect of the storage times of silicone-based soft lining material in water on hardness and water absorption of the material. Material and methods: In this study, silicone based soft denture liner Permaflex and isobutylmethacrylate-added form of the same material were used. The soft denture liners were processed according to manufac- turers’ instructions with the dimension insert ignore into journalissuearticles values(10x10x1mm); for water sorption tests and insert ignore into journalissuearticles values(10x10mm); for hardness tests, and then put in water bath at 37 0 C. During the periods of 1 st day, 1 st week, 1, 3 and 6 months, the measurements of water absorption and Shore A hardness values were performed. Data were evaluated using Man Whıtney U, Friedman and Wilcoxon tests insert ignore into journalissuearticles values( α =0.05);. Results: Regarding the hardness, a statistically signi- ficant difference was obtained among all Permaflex and Permaflex+isobutylmethacrylate groups when comparing all time periods insert ignore into journalissuearticles values(p<0,05);. A statistically sig- nificant difference was also found between the water absorption values only at the 3 rd month measurements insert ignore into journalissuearticles values(p<0,05);. In Permaflex group, water absorption value was statistically higher and hardness values were sta- tistically lower compared to Permaflex+ isobutylmet- hacrylate groups. While the water absorption values of both Permaflex and Permaflex + isobutylmethacrylate groups increased during the water holding periods, no statistically significant increase in hardness values was found. Conclusion: It has been determined that isobutylmethacrylate and storage in different time periods cause a change in the soft lining material in terms of hardness and water absorption.   Keywords: Soft lining materials, Isobutylmethacrylate, hardness, water sorption
Keywords : Yumuşak astar maddesi, izobutilmetakrilat, sertlik

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025