IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Current Research in Dental Sciences
  • Volume:29 Issue:3
  • İMPLANT ÜSTÜ OVERDENTURE PROTEZLERDE TUTUCU BAŞLIK DEFORMASYONUNA ALTERNATİF BİR ÇÖZÜM YÖNTEMİ: BİR ...

İMPLANT ÜSTÜ OVERDENTURE PROTEZLERDE TUTUCU BAŞLIK DEFORMASYONUNA ALTERNATİF BİR ÇÖZÜM YÖNTEMİ: BİR OLGU SUNUMU

Authors : Bilal HOLOĞLU, Zeynep YEŞİL DUYMUŞ
Pages : 497-500
Doi:10.17567/ataunidfd.604064
View : 16 | Download : 29
Publication Date : 2019-07-16
Article Type : Other Papers
Abstract :İmplant üstü overdenture protezler retansiyon ve stabiliteye olumlu katkılarından dolayı tam dişsiz hastaların yaşam kalitelerini artırmakta ve günümüzde standart bir tedavi protokolü olarak kabul edilmektedir. İmplant üstü overdenture protezlerde implantların üzerine topuz başlı ataşman, locator ataşman, barlı eklem veya mıknatıs gibi mekanizmalar yerleştirilerek tutuculuk sağlanmaktadır. Protezin içine kullanılan bağlantı mekanizmasına göre tutucu başlıklar yerleşti- rilmektedir. İmplant üstü overdenture protezlerin uzun dönem başarıları değerlendirildiğinde en sık karşılaşılan mekanik problemin tutucu başlıkların plastik yapıla- rındaki deformasyona bağlı retansiyon kaybı olduğu bilinmektedir. Çoğunlukla lastik yapıların yenilenmesi ile tutuculuk yeniden sağlanabilmektedir. Bu olgu sunumunda implant üstü overdenture protezindeki tutuculuk kaybı nedeniyle kliniğimize başvuran bir hastanın şikayetlerinin giderilmesine yönelik uygulanan alternatif yöntem hakkında bilgi verilmiştir. Anahtar Kelimler: Overdenture, implant, topuz başlı ataşman AN ALTERNATIVE SOLUTION METHOD FOR DEFORMATION OF RETENTIVE CAPS IN IMPLANT SUPPORTED OVERDENTURE PROSTHESIS: A CASE REPORT Nowadays implant supported overdenture dentures are accepted as a standard treatment protocol due to improving life quality of edentulous patients with their positive contribution on retention and stability. Some mechanisms such as ball attachment, locator attachment and magnet retained system might be used for providing retention of implant supported overdenture prosthesis. Retainer caps are placed according to the retention mechanism used in the prosthesis. It is known that the most common mechanical problem was loss of retention due to deformation of the plastic structures when the long-term success of implant overdenture prosthesis evaluated. Generally the retention can be restored again with renovation of plastic structures. In this case report i nformation was provided on an alternative method applied for the removal of the patient\`s complaints due to loss of retention of implant supported overdenture prosthesis. Keywords: Overdenture, implant, ball attachment
Keywords : Overdenture, implant

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025