IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Current Research in Dental Sciences
  • Cilt: 35 Sayı: 4
  • Comparison of the Effectiveness of Bleaching Treatment with Activation Using Polywave LED Light, Dio...

Comparison of the Effectiveness of Bleaching Treatment with Activation Using Polywave LED Light, Diode Laser and Er, Cr:YSGG Laser: An in Vitro Study

Authors : Latife Altınok Uygun, Cemile Yılmaz, Pınar Gül
Pages : 312-317
Doi:10.17567/currresdentsci.1470751
View : 92 | Download : 272
Publication Date : 2025-10-21
Article Type : Research Paper
Abstract :Objective: This study aimed to evaluate the efficacy of non-vital bleaching treatments activated by laser systems and polywave LED light. Methods: Forty-eight extracted maxillary incisors were artificially stained using sheep blood and then the initial colour values of the stained teeth were measured and recorded with a spectrophotometer. The teeth were randomly assigned to four groups (n = 12 per group): Group 1 (control) received 30-minute non-vital bleaching treatments with 35% hydrogen peroxide (H₂O₂); Group 2 received 35% H₂O₂ with a diode laser (940 nm); Group 3 received 35% H₂O₂ with an Er,Cr YSGG laser (2780 nm); and Group 4 received 35% H₂O₂ with polywave LED light (480 nm). Spectrophotometric evaluation of color change (ΔE00) was performed on days 1, 3, and 7 post-treatment. Results: Intergroup comparisons showed significantly lower ΔE00 values in Group 1 (control) and Group 4 (H₂O₂ + polywave LED light) compared to Groups 2 (H₂O₂ + diode laser) and 3 (H₂O₂ + Er,CrYSGG laser) across all time points (P < .05). No significant difference in ΔE00 was observed between Groups 2 and 3 at any time point (P > .05). Conclusion: Both the diode laser and Er,CrYSGG laser significantly enhanced the efficacy of non-vital bleaching. Although polywave LED light achieved adequate bleaching results, its activation was less effective than that of laser systems. Keywords: Color change, laser, LED, spectrophotometric analysis, teeth bleaching, nonvital
Keywords : Renk değişimi, lazer, LED, spektrofotometrik analiz, diş beyazlatma, nonvital

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026