IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • European Oral Research
  • Volume:16 Issue:3-4
  • Kuron-Köprü Protezlerinde Ölçü Yöntemleri ve Kauçuk Esaslı Ölçü Maddelerinin Karşılaştırılması(*)...

Kuron-Köprü Protezlerinde Ölçü Yöntemleri ve Kauçuk Esaslı Ölçü Maddelerinin Karşılaştırılması(*)

Authors : Pınar MERİÇ, Erdal POYRAZOĞLU
Pages : 318-324
View : 39 | Download : 10
Publication Date : 2013-06-25
Article Type : Research Paper
Abstract :  SONUÇ ve ÖZET Kauçuk esaslı iki ölçü maddesiyle 1 - Wash., 2 - Şırınga tekniği kullanılarak stoplu ve stopsuz özel kaşıklarla alınan ölçülerden elde edilen modellerde ana modele en yakın değerleri sağlayan yöntem araştırılmış ve Beerendonk kompasıyla yapdan ölçmeler karşılaştırılmıştır. Buna göre en uygun değerler: a — Her iki tip kaşığın kullanılmasıyla da şırınga tekniğinde, b — Wash tekni ğinin, stoplu kaşık kullanılarak diş kesilmeden önce ilk ölçü ve diş kesimi yapıldıktan sonra tüm ölçü yüzeyine ikinci ölçü uygulanan yönteminde elde edilmiştir. c — Değerler arasındaki farklılıklar küçük hacımlar için klinik olarak büyük bir dezavantaj göstermeyebilir ancak büyük hacimli geniş bölgelerin ölçüleri için kritik olabileceğini düşündürmektedir.  SUMMARY Impressions obtained with rubber base materials insert ignore into journalissuearticles values(Optosil + Xantopren and Permlastic); applying Wash and Syringe techniques were compared. Individual impression trays were prepared autopolymerisante acrylic resin with and without stops. Measurements were made with Beerendonk compass on the master and the dental stone models. Thus, a — Syringe technique using individual impression trays with and without stops, and b — Wash technique using individual impression tray with stops, besides taking the first impression prior to tooth reduction and applying the corrector material following the preparation showed maximum accuracy. c — The different findings in measurements may not be disadvantageous as clinically for impressions of small regions but the same assumption may not be acceptable for full mouth impressions.
Keywords :

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026