IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Environmental Research and Technology
  • Volume:5 Issue:1
  • Optimization of the effect of copper electrodes on the removal efficiency of 4-clorophenol from aque...

Optimization of the effect of copper electrodes on the removal efficiency of 4-clorophenol from aqueous solution by electrocoagulation

Authors : Gulizar KURTOGLU AKKAYA, Muhammed Kamil ÖDEN
Pages : 33-43
Doi:10.35208/ert.1014814
View : 61 | Download : 13
Publication Date : 2022-03-31
Article Type : Research Paper
Abstract :In this study, the investigation of 4-clorophenol insert ignore into journalissuearticles values(CP); removal from aqueous solutions using copper electrodes by electrocoagulation insert ignore into journalissuearticles values(EC); process was done. The effects of various experimental parameters such as pH, current density and exposure time, which affect the EC process, on 4-CP removal were investigated. To optimize the process, response surface methodology insert ignore into journalissuearticles values(RSM); Box Behnken Design was used by MINITAB program, a series of experimental sets were obtained and carried out. Afterward, 4-CP removal was analyzed and calculated. Results were entered into the MINITAB program as a response. At the end of the optimization, optimum operating conditions were determined as 74 mA/cm2, 45 min, 4.24 for current density, exposure times and pH, respectively. When the results were evaluated, approximately 92% phenol removal efficiencies were obtained. Additionally, according to the model results, it was understood that the factors with the greatest effect on 4-CP removal were the exposure time and current density and these had a linear effect, but the pH value did not have a significant effect.
Keywords : Copper, electrocoagulation, MINITAB, 4 clorophenol

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026