IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Acta Odontologica Turcica
  • Volume:40 Issue:3
  • Comparison of Apically Extruded Debris During Root Canal Instrumentation Using T-endo must, T-endo m...

Comparison of Apically Extruded Debris During Root Canal Instrumentation Using T-endo must, T-endo mis, and Reciproc Blue Files

Authors : Funda FUNDAOĞLU KÜÇÜKEKENCİ
Pages : 79-83
Doi:10.17214/gaziaot.1143423
View : 69 | Download : 46
Publication Date : 2023-09-04
Article Type : Research Paper
Abstract :OBJECTIVE: The aim of this study was to compare the effect of nickel-titanium file systems with different taper angles working with rotation and reciprocation motion on the amount of debris extruding apically. MATERIALS AND METHOD: The study was performed using the Myers and Montgomery model. Forty-five human maxillary anterior teeth were inserted into preweighed Eppendorf tubes and randomly classified into three groups. After manual glide-path preparation, the teeth in each group were instrumented to the working length set 1 mm short of the anatomical apex using the standard sequence provided by the manufacturers: Group 1: Reciproc Blue insert ignore into journalissuearticles values(Easy In Smile, New Jersey, USA);, Group 2: T-endo must insert ignore into journalissuearticles values(Dentac, İstanbul, Turkey);,Group 3: T-endo mis insert ignore into journalissuearticles values(Dentac, İstanbul, Turkey);. Root canals were irrigated with 10 mL 2.5% NaOCl, 17% EDTA, and distilled water between each file insertion. The tubes with collected debris were stored in an incubator at 70°C for 7 days. Measurement of the weight of extruded debris was performed by subtracting the pre-instrumentation from the post-instrumentation weight of the tubes. Data were analyzed using one-way ANOVA and Tukey’s Honest Significant Difference Test insert ignore into journalissuearticles values(α=0.05);. RESULTS: The weights of the apically extruded debris were 0.0094±0.0015 g in Group 1, 0.0075±0.0012 g in Group 2, and 0.0044±0.0010 g in Group 3, and the difference between all groups was statistically significant insert ignore into journalissuearticles values(p<0.05);. CONCLUSION: The amount of apically extruded debris is related to the taper angle of the file used and the kinematics of the file.
Keywords : apikal foramen, endodonti, kök kanalını hazırlama, kök kanal tedavisi

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026