- Medical Research Reports
- Volume:1 Issue:3
- An Open Label Prospective Randomized Trial to Compare The Efficacy Tolerability and Cost Effectivene...
An Open Label Prospective Randomized Trial to Compare The Efficacy Tolerability and Cost Effectiveness of Brand Name Versus Two Different Generic Drug of Fixed Combination Dorzolamide 2% and Timolol 0.5% in The Treatment of Primary Open Angle Glaucoma
Authors : Mustafa ELİAÇIK
Pages : 55-60
View : 42 | Download : 11
Publication Date : 2018-12-31
Article Type : Research Paper
Abstract :Purpose: To compare the efficacy tolerability and cost effectiveness of brand name versus two different generic drug of fixed combination dorzolamide 2% and timolol 0.5% in the treatment of primary open angle glaucoma. Methods: Sixty-six eyes of 66 patients with newly diagnosed, open-angle glaucoma were included in this prospective, examiner masked, randomized study. All patients underwent routine ophthalmic examinations at baseline and 6 months of treatment. After initial examination, patients were randomly divided into three groups and prescribed to use fixed combination treatment of dorzolamide/timolol insert ignore into journalissuearticles values(D/T); brand name and two different generic name drops. Retrobulbar blood flow was assessed with color Doppler imaging insert ignore into journalissuearticles values(CDI);. At end-of-treatment assessments, patients were requested to fill in a questionnaire based on `the Comparison of Ophthalmic Medications for Tolerability`. Results: Intraocular pressure insert ignore into journalissuearticles values(IOP); and CDI measurements were similar at baseline. Compared to baseline, the brand name drop had a better resistive index lowering effect than two other generic drugs , however the difference was not statistically significant insert ignore into journalissuearticles values(p=0.056);. Brand name D/T fixed combination provided greater significant mean IOP reductions from baseline than two other generic name drops insert ignore into journalissuearticles values(p=0.001);. There were no statistically significant differences in the IOP lowering effect between generic drops insert ignore into journalissuearticles values(p=0.562);. Tolerability was similar between groups. Generic bottles failed to last a month for 80% patients. Conclusions: Brand name product of D/T fixed combination is exactly more effective in IOP reduction and seems to be having a better lowering effect on resistive index, even a statistically significant result was not found.Keywords : generic drug, cost effectiveness, retrobulbar bloodflow, color doppler imaging
ORIGINAL ARTICLE URL
