IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Abant Tıp Dergisi
  • Volume:12 Issue:2
  • Effect of Photochromic Senofilcon A Contact Lens on Total Aberrations of the Eye

Effect of Photochromic Senofilcon A Contact Lens on Total Aberrations of the Eye

Authors : Deniz KILIC, Muhammed Raşit SİREM, Yunus Naci AZİZ, Semra KOCA, İbrahim TOPRAK
Pages : 98-104
Doi:10.47493/abantmedj.1236292
View : 96 | Download : 55
Publication Date : 2023-08-31
Article Type : Research Paper
Abstract :Purpose: To investigate the effect of newly designed photochromic Senofilcon-A lensinsert ignore into journalissuearticles values(PCL); on optical aberrations of the eye insert ignore into journalissuearticles values(total insert ignore into journalissuearticles values(TA); and high-order-aberrations insert ignore into journalissuearticles values(HOA);); under ambient illumination conditions. Methods: In this retrospective study, 40 eyes of 20 volunteers were fitted with a non-photochromic Senofilcon-A contact lens on the right eye, a PCL on left eye. Subjects were evaluated in terms of best-corrected visual-acuity. Aberrometric measurements were obtained at baselineinsert ignore into journalissuearticles values(lens-free);, with activated and deactivated PCL in 3 mm, 6 mm and maximum pupil size. Results: In lens-free situation there was no difference in terms of TA and HOAsinsert ignore into journalissuearticles values(for 3mm, 6mm and max-pupil-size, TA; P= .456; P= .687; P= .899 and HOA; P = .226; P = .259; P = .442 respectively);.In all pupil diameters, in the PCL group compared to the standard lens group, there was a slight increase in total aberrations independent of lens activation, which was not statistically significantinsert ignore into journalissuearticles values(for 3mm,6mm and max-pupil-size, activated lens situation;P = .523; P = .622; P = .244 and deactivated lens situation; P = .785; P = .357; P = .201,respectively);. Contrary to total aberrations, higher order aberrations were non-significantly slightly decreased in the PCL groupinsert ignore into journalissuearticles values(for 3mm,6mm and max-pupil-size, activated lens situation; P = .235; P = .661; P = .841 and deactivated lens situation;P = .245; P = .071; P = .231,respectively);. Conclusion: The PCL produces similar TA and HOAs with the non-photochromic soft contact lens in both activated and deactivated situation. PCLs can be preferred for those who need uninterrupted vision in variable light conditions.
Keywords : aberasyon, kontakt lens, fotokoromik, ultraviyole

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026