IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Sabuncuoglu Serefeddin Health Sciences
  • Volume:4 Issue:1
  • COMPARISON OF MARGINAL ADAPTATION OF DIFFERENT FRAMEWORK MATERIALS BEFORE AND AFTER CEMENTATION: AN ...

COMPARISON OF MARGINAL ADAPTATION OF DIFFERENT FRAMEWORK MATERIALS BEFORE AND AFTER CEMENTATION: AN IN VITRO STUDY

Authors : Cevdet ÇALIŞKAN, Fatih DEMİRCİ, Merve BİRGEALP ERDEM
Pages : 28-45
Doi:10.55895/sshs.1050112
View : 21 | Download : 15
Publication Date : 2022-04-30
Article Type : Research Paper
Abstract :Purpose: This study aimed to compare the marginal adaptation of different framework materials polyetheretherketone insert ignore into journalissuearticles values(PEEK);, zirconia, and cobalt-chromium insert ignore into journalissuearticles values(Co-Cr); through direct metal laser sintered insert ignore into journalissuearticles values(DMLS); and conventional casting insert ignore into journalissuearticles values(CC); in fixed prosthetic restorations. Materials and Methods: A total of 80 stainless steel dies were embedded in silicone molds, and the master models obtained were divided into four groups insert ignore into journalissuearticles values(n=20);: PEEK, zirconia, Co-Cr through DMLS and CC frameworks. The vertical marginal gap was measured by stereomicroscope at ×20 magnification. In addition to descriptive statistics in the evaluation of data, one-way ANOVA was used with the post hoc multiple comparison test Tamhane’s T2, as the data were normally distributed and variances differed according to the Kolmogorov–Smirnov and Shapiro–Wilk tests. Results: There was a statistically significant difference in vertical marginal gap before and after cementation in all groups insert ignore into journalissuearticles values(p<0.05);. Conclusion: Before and after cementation, vertical marginal gap values of laser sintered Co-Cr, zirconia, and PEEK frameworks were clinically acceptable. Keywords: PEEK; Marginal Adaptation; Laser Sintered Co-Cr; Zirconia; Framework
Keywords : PEEK, Marginal Adaptation, Laser Sintered Co Cr, Zirconia, Framework

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025