  • Intraocular Pressure Measurements with Pneumotonometer and Tono-Pen in Patients Using Topical Antigl...

Intraocular Pressure Measurements with Pneumotonometer and Tono-Pen in Patients Using Topical Antiglaucomatous Medication Due to Primary Open Angle Glaucoma

Authors : Kemal ÖZÜLKEN, Çağrı İLHAN
Pages : 59-62
Doi:10.31067/acusaglik.833696
View : 38 | Download : 21
Publication Date : 2020-12-16
Article Type : Research Paper
Abstract :Purpose:To compare intraocular pressure insert ignore into journalissuearticles values(IOP); measurements obtained with Goldmann applanation tonometer insert ignore into journalissuearticles values(GAT);, pneumotonometer, and Tono-pen in patients using topical antiglaucomatous medication due to primer open angle glaucoma. Patients and Methods:The medical documents of patients using topical antiglaucomatous medication due to primary open angle glaucoma were retrospectively investigated in this non-randomized case-control study. Only right eyes of 113 patients were included. The IOP measurements obtained with pneumotonometer and Tono-Pen were statistically compared with the IOP measurements obtained with GAT, and the correlations between series were investigated. Results:The mean age was 57.41  11.02 years insert ignore into journalissuearticles values(41 – 82 years); in 113 patients, 52 males and 61 females insert ignore into journalissuearticles values(p = 0.638);. The mean IOP was 21.04  5.40 mmHg insert ignore into journalissuearticles values(12 – 46 mmHg); with GAT, 20.19  5.61 mmHg insert ignore into journalissuearticles values(12 – 48 mmHg); with pneumotonometer and 17.37  4.99 mmHg with tonopen insert ignore into journalissuearticles values(8 – 44 mmHg);. The mean IOP values obtained with both pneumotonometer and tonopen were significantly lower than the mean IOP obtained with GAT insert ignore into journalissuearticles values(p <0.001 for both);. IOP measurements obtained with both pneumotonometer insert ignore into journalissuearticles values(r = 0.96 and p <0.001); and tonopen insert ignore into journalissuearticles values(r = 0.83 and p <0.001); were significantly correlated with IOP measurements obtained with GAT. Conclusion:IOP measurements obtained with pneumotonometer and tonopen in patients using topical antiglaucomatous medication due to primer open angle glaucoma is lower and correlated with the measurements obtained with GAT.
Keywords : Glaucoma, primary open angle glaucoma, Goldmann applanation tonometer, pneumotonometer, Tono Pen

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.