IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Celal Bayar Üniversitesi Fen Bilimleri Dergisi
  • Volume:13 Issue:3
  • Determination of Folic Acid by Ultra-High Performance Liquid Chromatography in Certain Malt-based Be...

Determination of Folic Acid by Ultra-High Performance Liquid Chromatography in Certain Malt-based Beverages after Solid-Phase Extraction

Authors : Elif Mine ÖNCÜKAYA
Pages : 623-630
Doi:10.18466/cbayarfbe.339315
View : 22 | Download : 10
Publication Date : 2017-09-30
Article Type : Research Paper
Abstract :The aim of the present work was to develop and validate an efficient Ultra-High Performance Liquid Chromatography (UHPLC) method for the determination of folic acid (FA) in malt-based beverages. Solid-phase extraction (SPE) procedure was used for cleanup and preconcentration of the malt-based beverages before the UHPLC analysis. The analysis was performed in a C18 column (2.1x50 mmx1.8 µm) using a solvent system of ACN: 0.1 % formic acid in water (10:90, v/v) by isocratic elution. Injection volume was 5 µL. The flow rates of the mobile phase were maintained at 0.2 mL min ‒1 for 0.00–4.00 min and 0.5 mL min ‒1 for 4.01–12.00 min. Methyl paraben was used as the internal standard (IS). The FA and IS signals were detected at 284 nm and 254 nm, respectively. Under these conditions, FA and IS were separated in 3.6 min and 11.4 min, respectively. The method was successfully validated in terms of precision, accuracy, linearity, limits of detection (LOD) and quantification (LOQ) parameters. The relative standard deviations for intra- and inter-day precision were less than 1.5%. Good linearity with a high correlation coefficient was achieved over the concentration range of 20.13 µg L −1   – 2004 µg mL −1 for FA. The LOD and LOQ values were 6.66 µg L −1 and 20.13 µg L −1 , respectively . Good recovery values were found ranged between 99.1% and 106% for boza and vitamin fortified malt drink. The proposed method was successfully applied for the determination of FA in malt beers, vitamin fortified malt drinks and boza samples.
Keywords : Boza, Folic acid, Malt based beverages, Method development, UHPLC, Validation

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025