IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Dicle Üniversitesi Mühendislik Fakültesi Dergisi
  • Volume:12 Issue:4
  • Mapping of electric field intensity distribution in the 27 MHz - 3000 MHz frequency range in Diyarba...

Mapping of electric field intensity distribution in the 27 MHz - 3000 MHz frequency range in Diyarbakir city center

Authors : Mehmet Veysel ÖNLÜ, Hüseyin ÖZMEN, Muhammed Bahaddin KURT
Pages : 595-601
Doi:10.24012/dumf.1001977
View : 22 | Download : 14
Publication Date : 2021-09-29
Article Type : Research Paper
Abstract :It is evident that the rapid development in science and technology has enabled various electronic devices and communication systems. However, there are also undesired effects of those devices on human health. One of those effects is the electromagnetic fields that exceeds the limits. Therefore, the electromagnetic fields emitted by the devices should not exceed a certain level. In that respect, different institutions around the world have determined the certain limits. One of the most important of these organizations in the world is the International Commission on Non-Ionizing Radiation Protection (ICNIRP). Similar to the other existing organizations, the Information and Communication Technologies Authority (BTK) is the responsible authority in Turkey. In this study, electric field intensity values were measured using the drive test method with the Selective Radiation Meter (SRM-3006) device on the main streets in Diyarbakır City Center. Obtained measurement values were shown on dot thematic maps, two-dimensional maps and three-dimensional maps. As a result, locations with the highest electric field intensity were determined by these maps. In addition, the obtained results were compared with the limit values determined by ICNIRP and BTK and it was seen that the measured electric field intensity values did not exceed the exposure limits.
Keywords : electric field intensity, mapping, mobile measurement

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025