Journal article
Thermal and mechanical analysis of thermal power plant ashes, cement and resin composites
Abstract
This study used thermal power plant fly ash insert ignore into journalissuearticles values(FA); and bottom ash insert ignore into journalissuearticles values(BA); as fill materials and investigated the thermal properties of composites made of cement and pine tree resin binders. For each ash group, 36 samples were prepared by adding 50% cement and 1% to 2% resin as binders. i); FA samples had 23.18%, 22.99%, and 77.01% lower density, thermal conductivity, and compressive strength than BA samples, respectively. FA samples had 9.42% higher porosity than BA samples. ii); FA insert ignore into journalissuearticles values(0.177 W/mK); and BA insert ignore into journalissuearticles values(0.221 W/mK); samples with resin and cement had the lowest heat transfer coefficients. iii); FA insert ignore into journalissuearticles values(14.46 MPa); and BA insert ignore into journalissuearticles values(36.96 MPa); samples insert ignore into journalissuearticles values(resin + cement binder); had the highest compressive strength values.
Keywords
86 views · 75 downloads