THE EFFECTS of DIFFERENT RATIO for GADOLINIUM (GD) and TUNGSTEN (W) on NEUTRON CONTAMINATION CAUSED by MEDICAL LINAC COLLIMATOR

Authors : Yiğit Ali ÜNCÜ, Onur KARAMAN, Aycan ŞENGÜL, Gizem ŞİŞMAN, Kadir AKGÜNGÖR
Pages : 197-206
View : 25 | Download : 15
Publication Date : 2021-12-31
Article Type : Research Paper
Abstract :The linear accelerators (LINACs) produce high-energy X-rays and electron beams for the treatment of cancer patients. The basis of radiation therapy is based on the interaction between substance and radiation. LINAC as External beam radiotherapy, neutron contamination is produced in electron beams of medical LINAC by the contribution of the primary and the secondary collimators are founded. Consequently, the resulting photoneutrons can easily be scattered and spread into the clinical room. Thus, it is recommended that treatment planning performed should not be ignored in the tumor volume of the patient and areas outside this volume. The contribution of the primary collimator and the secondary collimators to the neutron contamination was found to be approximately 52% and 30%, respectively. This paper’s objective is to determine the neutron dose contamination from different materials in a LINAC. The effects of using different material ratios such as Gadolinium (Gd) and Tungsten (W) in secondary collimators on neutron contamination have been investigated by using Geant4-based Architecture for Medicine-Oriented Simulations (GAMOS) and TALYS 1.95 codes.
Keywords : Medical LINAC, Photo neutron, Secondary Collimator, Neutron Contamination, GAMOS, TALYS 1 95

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.