IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Düzce Üniversitesi Bilim ve Teknoloji Dergisi
  • Volume:12 Issue:1
  • Thermo-Fluidic Analysis of Pulsating Heat Pipes Charged with Water-Based Immiscible Fluid Pairs

Thermo-Fluidic Analysis of Pulsating Heat Pipes Charged with Water-Based Immiscible Fluid Pairs

Authors : Burak Markal, Ramazan Varol
Pages : 63-80
Doi:10.29130/dubited.1115581
View : 39 | Download : 37
Publication Date : 2024-01-26
Article Type : Research Paper
Abstract :Immiscible fluids may provide operational flexibility for pulsating heat pipes (PHPs) due to thermo-hydrodynamic diversity lead by each pure component. In this regard, present paper focuses on the thermo-fluidic analysis of non-uniform pulsating heat pipes charged with water-based immiscible fluid pairs. Research parameters cover gravity effect via the inclination angles (IA) of 0o and 90o, and fluid pair effect via two different water-based immiscible binary fluids as Water (W) – Hexane (H), and Water (W) – Pentane (P). The volumetric mixing ratios are W:H=1:1, 1:4, 4:1, 1:0, 0:1, and W:P=1:1, 1:4, 4:1, 1:0, 0:1; and the non-uniform flat plate type pulsating heat pipe (FP-CLPHP) has alternating-sequence parallel channels. The experiments are performed at the filling ratio of 40% (FR=40%), and flow phenomena is visualized. As some conclusions; at vertical orientation, the FP-CLPHPs having binary fluids of water-pentane show better thermal performance compared to the pure counterparts. Especially, the heat transfer characteristics of W:P=1:1 are the best ones among all the pure and binary fluids. On the other hand, as a conclusion of combination of non-uniform design and suitable thermophysical properties, the FP-CLPHPs charged with pure pentane, pure hexane or binary fluid of W:P=1:4 can work independent from gravitational force.
Keywords : Karışmama, Atımlı ısı borusu, Akışkan çiftleri, Termo akış analizi

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025