- Afyon Kocatepe Üniversitesi Fen Ve Mühendislik Bilimleri Dergisi
- Cilt: 25 Sayı: 3
- Investigation of Centrifugal Pump Used in Irrigation by Numerical (CFD Analysis) and Experimental Me...
Investigation of Centrifugal Pump Used in Irrigation by Numerical (CFD Analysis) and Experimental Methods
Authors : Mehmet Kurt, Kazım Çarman
Pages : 686-694
Doi:10.35414/akufemubid.1510101
View : 32 | Download : 48
Publication Date : 2025-06-10
Article Type : Research Paper
Abstract :The goal in centrifugal pump designs is to achieve maximum efficiency. Even small percentage increases in pump efficiency provide high overall energy savings in pumps that operate for long periods of time, especially those that use high-power motors. While fan and casing structures are designed in line with this goal, many structural features affect the efficiency of the pumps. In the study, pump performance values of the 5” horizontal shaft centrifugal pump at different flow rates were measured in the laboratory. Depending on the change in pump flow rates, it was determined that the pump power consumption varied between 15-42kW and the efficiency values varied between 32.63-55.57%. Considering the statistical compatibility of the measured pump performance values with the values obtained by CFD, it was determined that the coefficient of determination of the measured and predicted values varied between 0.870 and 0.936, which is quite high. The mean absolute percentage error was determined to be well below the acceptable value of 10%.Keywords : Santrifüj pompa, güç tüketimi, manometrik yükseklik, verim, HAD
ORIGINAL ARTICLE URL