IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Iğdır Üniversitesi Fen Bilimleri Enstitüsü Dergisi
  • Volume:14 Issue:4
  • Development Of Non-Enzymatic Electrochemical P-Nitrophenol Sensor Based On Carboxylated Graphene Oxi...

Development Of Non-Enzymatic Electrochemical P-Nitrophenol Sensor Based On Carboxylated Graphene Oxide Modified Glassy Carbon Electrode

Authors : Zhivan Tayeb Ali Husseın, Muhammet Güler
Pages : 1672-1683
Doi:10.21597/jist.1514004
View : 97 | Download : 67
Publication Date : 2024-12-01
Article Type : Research Paper
Abstract :The current work reports a new electrochemical p-nitrophenol (p-NP) sensor which depends upon the carboxyl functionalized graphene oxide (GO-COOH) modified of glassy carbon electrode (GCE). Scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR) were performed to examine the morphology of GO-COOH. The GO-COOH/GCE sensor was electrochemically characterized by means of chronoamperometry, electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and linear sweep voltammetry (LSV). A distinct cathodic peak of p-NP was seen on the GO-COOH/GCE in 0.1 M phosphate buffer solution (pH 6.5). The sensor displayed three dynamic linear ranges for p-NP under optimum conductions. The linear detection ranges were 2.0×10-7 - 2.95×10-6 M, 2.95×10-6 – 2.74×10-4 M, and 2.74×10-4 – 7.25×10-4 M with the sensitivities of 39622.1 A/Mm2, 9959.3 A/Mm2, and 6395 A/Mm2, respectively. It was found that detection limit (LOD) was 5.3×10-8 M at a signal to noise ratio of 3. The GO-COOH/GCE demonstrated satisfactory performance factors such as selectivity and repeatability. Additionally, the GO-COOH/GCE sensor was demonstrated to be utilized to electrochemically determine p-NP in a variety of water samples.
Keywords : Electrochemical sensor, Carboxylated graphene oxide, p Nitrophenol

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026